Vaillant boiler installation · Oxfordshire
Vaillant boiler installation in Oxfordshire
Vaillant Advance installers offering new boilers, boiler replacements and heating upgrades. Explore ecoTEC and ecoFIT boilers, then choose a system planned around your home and everyday hot-water needs.




Vaillant boilers, chosen around your home
For Vaillant boiler installation in Oxfordshire, talk to Oxyplumb about the whole heating system. First, we check your existing boiler, radiators, water supply and controls. Then, we explain the practical differences between suitable Vaillant models and provide a clear installation quotation.
We are Vaillant Advance installers, offering the maximum 10-year guarantee on our relevant Vaillant installations. Our team takes care of specifying, fitting, commissioning and registering your new boiler.
Explore the Vaillant boiler range
First, compare the Vaillant boiler ranges below, using the images and key facts alongside each description. Then, open the model specifications to see the published figures, or ask our team to explain the choices for your home.
Gas combi and storage boilers

Combi
ecoTEC pro
First, we check how this range would suit your Vaillant boiler installation. The ecoTEC pro combi range offers 24, 28 and 30kW models. In addition, aquaCOMFORT pre-heating and a stainless steel heat exchanger support straightforward everyday operation.
Compare model specifications
| Technical data | Unit of measure | ecoTEC pro 24 | ecoTEC pro 28 | ecoTEC pro 28 LPG | ecoTEC pro 30 |
|---|---|---|---|---|---|
| Boiler type | combi | combi | combi | combi | |
| Article number | 0010021836 | 0010021837 | 0010021838 | 0010016538 | |
| Gas Council number | 47-044-88 | 47-044-89 | 47-044-90 | 47-044-52 | |
| Boiler dimensions (HxWxD) | mm | 720 x 440 x 338 | 720 x 440 x 338 | 720 x 440 x 338 | 720 x 440 x 338 |
| Nominal heat output range at 50/30˚C (Condensing mode) | kW | 5.9 – 24.8 | 5.9 – 25.9 | 6.9 – 25.3 | 6.9 – 25.7 |
| Nominal heat output range at 80/60˚C (Non condensing mode) | kW | 5.2 – 23.0 | 5.2 – 24.0 | 7.2 – 24.0 | 6.2 – 24.4 |
| Maximum flow temperature | ˚C | 85 | 85 | 85 | 85 |
| Flow temperature range | ˚C | 30 – 85 | 30 – 85 | 30 – 85 | 30 – 85 |
| Flow temperature factory setting | ˚C | 75 | 75 | 75 | 75 |
| Approximate condensate volume at 50/30˚C | litres/hr | 1.9 | 1.9 | 1.9 | 2:5 |
| Modulation (max/min) | 1 : X | 1:4.3 | 1:5 | 1:3.6 | 1:3.8 |
| Maximum heat output for water generation | kW | 23.4 | 27.2 | 27.2 | 30 |
| Lowest water pressure to operate boiler | bar | 0.8 | 0.8 | 0.8 | 0.8 |
| Lowest water flow for operation | l/min | 2.0 | 2.0 | 2.0 | 2.0 |
| Lowest water pressure for maximum flow rate | bar | 0.8 | 0.8 | 0.8 | 0.8 |
| Domestic hot water flow rate (at DT = Δ35K) * | l/min | 9.6 | 11.1 | 11.1 | 12.3 |
| Hot water output temperature range | ˚C | 35 – 65 | 35 – 65 | 35 – 65 | 35 – 65 |
| Expansion vessel size | lites | 8 | 8 | 8 | 8 |
| Gas inlet connection (pipe size) | mm | 15 | 15 | 15 | 15 |
| Heating flow and return connections (pipe size) | mm | 22 | 22 | 22 | 22 |
| Hot and cold water connections (pipe size) | mm | 15 | 15 | 15 | 15 |
| Heat exchanger material | Stainless/Aluminium | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Boiler lift weight (Dry boiler) | kg | 38 | 38 | 38 | 39 |
| NOx | 6 | 6 | 6 | 6 | |
| NOx (En 15502-2-1) | mg/kWh | 27 | 33 | 33 | 30 |
| ErP efficiency | % | 93 | 93 | 93 | 93 |
| ErP decibel rating (sound power) | dBa | 49 | 49 | 49 | 49 |
| Maximum horizontal flue length 60/100 | m | 12 | 12 | 12 | 12 |
| Maximum vertical flue length 60/100 | m | 16 | 16 | 16 | 16 |
| Maximum horizontal flue length 80/125 | m | 39 | 39 | 39 | 39 |
| Maximum vertical flue length 80/125 | m | 41 | 41 | 41 | 41 |

Combi / system
ecoTEC plus Combi & System
Also, we compare space and hot-water requirements for your Vaillant boiler installation. The remastered ecoTEC plus uses IoniDETECT combustion control and works with myVAILLANT connect. In addition, the range includes a storage-combi option for higher hot-water demand.
Compare model specifications
| Technical data | Unit of measure | ecoTEC plus 826 – 26kW | ecoTEC plus 832 – 32kW | ecoTEC plus 836 – 36kW | ecoTEC plus 840 – 40kW | ecoTEC plus 940 – 40kW |
|---|---|---|---|---|---|---|
| Boiler type | Combi | Combi | Combi | Combi | Combi | |
| LPG compatible | Yes – adaptive | Yes – adaptive | Yes – adaptive | No | No | |
| Article number | 0010036015 | 0010036016 | 0010036017 | 0010036018 | 0010036114 | |
| PCDB number | TBC | TBC | TBC | TBC | TBC | |
| Boiler dimensions (HxWxD) | mm | 720 x 440 x 352 | 720 x 440 x 352 | 720 x 440 x 352 | 720 x 440 x 386 | 720 x 440 x 580 |
| Side clearance | mm | 5 | 5 | 5 | 5 | 5 |
| Top clearance (With 60/100 flue) | mm | 165 | 165 | 165 | 165 | 165 |
| Top clearance if using rear flue | mm | N/A | N/A | N/A | N/A | N/A |
| Bottom clearance | mm | 180 | 180 | 180 | 180 | 180 |
| Front clearance ~ | mm | 500 | 500 | 500 | 500 | 500 |
| Nominal heat output range at 50/30°C (Condensing mode) | kW | 2.8 – 21.2 | 3.9 – 26.5 | 4.2 – 32.2 | 5.0 – 32.3 | 5.0 – 32.3 |
| Nominal heat output range at 80/60°C (Non condensing mode) | kW | 2.5 – 19.8 | 3.5 – 24.9 | 3.7 – 29.9 | 4.5 – 29.8 | 4.5 – 29.8 |
| Lowest water pressure to operate boiler | bar | 0.7 | 0.7 | 0.7 | 0.7 | 0.7 |
| Lowest water flow for operation | l/min | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 |
| Domestic hot water flow rate (at Δ30˚C) ** | l/min | 12.4 | 15.2 | 17.0 | 19.0 | 21.0 |
| Domestic hot water flow rate (at Δ35˚C) ** | l/min | 10.6 | 13.0 | 14.6 | 16.3 | 18.0 |
| Hot water output temperature range | ˚C | 35-65 | 35-65 | 35-65 | 35-65 | 35-65 |
| Gas inlet connection (pipe size) | mm | 15 | 15 | 15 | 22 | 22 |
| Heating flow and return connections (pipe size) | mm | 22 | 22 | 22 | 22 | 22 |
| Hot and cold water connections (pipe size) | mm | 15 | 15 | 15 | 15 | 15 |
| Heat exchanger material | Stainless/ Aluminium | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Filling loop supplied | YES/NO | Yes | Yes | Yes | Yes | Yes |
| Boiler lift weight (Dry boiler) | kg | 36 | 37 | 37 | 41 | 60 |
| Spacer frame available | YES/NO | Yes | Yes | Yes | Yes | No |
| NOx (En 15502-2-1) | mg/kWh | 33.0 | 27.0 | 28.0 | 26.0 | 26.0 |
| ErP efficiency | % | 93 | 94 | 94 | 94 | 94 |
| ErP decibel rating (sound power) | dB(A) | 46 | 45 | 47 | 49 | 49 |
| ErP efficiency Heating/DHW | A+++ to D | A/A | A/A | A/A | A/A | A/A |
| PCDB annual efficiency (SAP 2009/2012) | % | TBC | TBC | TBC | TBC | TBC |
| Maximum horizontal flue length 60/100 | m | 10 | 8 | 8 | 8 | 8 |
| Maximum vertical flue length 60/100 | m | 10 | 8 | 8 | 8 | 8 |
| Maximum horizontal flue length 80/125 | m | 28 | 28 | 28 | 28 | 28 |
| Maximum vertical flue length 80/125 | m | 30 | 30 | 30 | 30 | 30 |
| Rear flue options | YES/NO | No | No | No | No | No |
| Permissible flue classifications | C13, C33, C43, C53 | C13, C33, C43, C53 | C13, C33, C43, C53 | C13, C33, C43, C53 | C13, C33, C43, C53 |
Vaillant range information · Detailed technical source · Domestic range technical brochure

Combi / system / regular
ecoFIT pure Combi, System & Open Vent
Before your Vaillant boiler installation, we assess the existing system and recommend a suitable model. The ecoFIT pure family includes combi, system and open-vent formats. In addition, an aluminium heat exchanger and top or rear flue options give us flexibility when planning the installation.
Compare model specifications
| Combi model | 825 | 830 | 835 |
|---|---|---|---|
| Hot-water output (kW) | 25.7 | 30.6 | 35.7 |
| Hot-water flow at 35°C rise (l/min) | 10.4 | 12.2 | 14.1 |
| Case H × W × D (mm) | 702 × 390 × 295 | 702 × 390 × 295 | 702 × 390 × 295 |
| ErP efficiency (%) | 94 | 94 | 94 |
| Sound power dB(A) | 49 | 51 | 52 |
| Technical data | Unit of measure | ecoFIT pure 412 | ecoFIT pure 415 | ecoFIT pure 418 | ecoFIT pure 425 | ecoFIT pure 430 | ecoFIT pure 435 |
|---|---|---|---|---|---|---|---|
| Boiler type | open vent | open vent | open vent | open vent | open vent | open vent | |
| Signature model output | 12kW | 15kW | 18kW | 25kW | 30kW | 35kW | |
| Article number | 0010020400 | 0010020401 | 0010020402 | 0010020403 | 0010020404 | 0010020405 | |
| Gas Council number | 41-694-08 | 41-694-09 | 41-694-10 | 41-694-11 | 41-694-12 | 41-694-19 | |
| Boiler dimensions (HxWxD) | mm | 600 x 375 x 295 | 600 x 375 x 295 | 600 x 375 x 295 | 600 x 375 x 295 | 600 x 375 x 295 | 600 x 375 x 295 |
| Nominal heat output range at 50/30˚C (Condensing mode) | kW | 4.7 – 12.8 | 4.7 – 15.9 | 5.2 – 19.1 | 6.4 – 26.5 | 7.4 – 31.8 | 7 – 35.8 |
| Nominal heat output range at 80/60˚C (Non condensing mode) | kW | 4.5 – 12.3 | 4.5 – 15.2 | 5 – 18.3 | 6.1 – 25.4 | 7.1 – 30.5 | 7.2 – 34.8 |
| Maximum flow temperature | °C | 80 | 80 | 80 | 80 | 80 | 80 |
| Flow temperature range | °C | 10 – 80 | 10 – 80 | 10 – 80 | 10 – 80 | 10 – 80 | 10 – 80 |
| Flow temperature factory setting | °C | 75 | 75 | 75 | 75 | 75 | 75 |
| Approximate condensate volume at 50/30°C | litres/hr | 1.23 | 1.53 | 1.84 | 2.55 | 3.06 | 3.65 |
| Modulation (max/min) | 1 : X | 1:3.3 | 1:4 | 1:5 | 1:4.9 | 1:4.9 | 1:4.9 |
| Maximum heat output for water generation | kW | 15 | 18 | 25.2 | 30 | 35 | 35 |
| Lowest water pressure to operate boiler | bar | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
| Lowest water flow for operation | l/min | – | – | – | – | – | – |
| Lowest water pressure for maximum flow rate | bar | – | – | – | – | – | – |
| Domestic hot water flow rate (at DT = Δ35K) * | l/min | – | – | – | – | – | – |
| Hot water output temperature range | ˚C | – | – | – | – | – | – |
| Expansion vessel size | litres | – | – | – | – | – | – |
| Gas inlet connection (pipe size) | mm | 15 | 15 | 15 | 15 | 15 | 15 |
| Heating flow and return connections (pipe size) | mm | 22 | 22 | 22 | 22 | 22 | 22 |
| Hot and cold water connections (pipe size) | mm | 15 | 15 | 15 | 15 | 15 | 15 |
| Heat exchanger material | Stainless/Aluminium | Aluminium | Aluminium | Aluminium | Aluminium | Aluminium | Aluminium |
| Boiler lift weight (Dry boiler) | kg | 22 | 22 | 22 | 22 | 22 | 22 |
| NOx class | 5 | 5 | 5 | 5 | 5 | 5 | |
| NOx (En 15502-2-1) | mg/kWh | 32 | 33 | 39 | 39 | 40 | 32 |
| ErP efficiency | % | 94 | 94 | 94 | 94 | 94 | 94 |
| ErP decibel rating (sound power) | dBa | 45 | 48 | 51 | 52 | 55 | 55 |
| Maximum horizontal flue length 60/100 | m | 10 | 10 | 10 | 10 | 10 | 10 |
| Maximum vertical flue length 60/100 | m | 10 | 10 | 10 | 10 | 10 | 10 |
| Maximum horizontal flue length 80/125 | m | 25 | 25 | 25 | 25 | 25 | 25 |
| Maximum vertical length 80/125 | m | 25 | 25 | 25 | 25 | 25 | 25 |
| Rear flue options | YES/NO | Yes | Yes | Yes | Yes | Yes | Yes |
Gas system boilers

System
ecoTEC exclusive
First, we check how this range would suit your Vaillant boiler installation. The current UK ecoTEC exclusive is a 27kW system boiler with Green iQ technology. Therefore, we compare it with your cylinder, heating demand and control preferences.
Compare model specifications
| Technical data | Unit of measure | ecoTEC exclusive 627 |
|---|---|---|
| Boiler type | system | |
| Signature model output | 27kW | |
| Article number | 0010017063 | |
| Gas Council number | 41-694-02 | |
| Boiler dimensions (HxWxD) | mm | 720 x 440 x 338 |
| Nominal heat output range at 50/30˚C (Condensing mode) | kW | 4.2 – 26.7 |
| Nominal heat output range at 80/60˚C (Non condensing mode) | kW | 3.7 – 24.7 |
| Maximum flow temperature | ˚C | 80 |
| Flow temperature range | ˚C | 30 – 80 |
| Flow temperature factory setting | ˚C | 75 |
| Approximate condensate volume at 50/30˚C | litres/hr | 2.52 |
| Modulation (max/min) | 1 : X | 1:8.1 |
| Maximum heat output for water generation | kW | 30 |
| Lowest water pressure to operate boiler | bar | – |
| Lowest water flow for operation | l/min | – |
| Lowest water pressure for maximum flow rate | bar | 0.8 |
| Domestic hot water flow rate (at DT = Δ35K) * | l/min | – |
| Hot water output temperature range | ˚C | – |
| Expansion vessel size | litres | 10 |
| Gas inlet connection (pipe size) | mm | 15 |
| Heating flow and return connections (pipe size) | mm | 22 |
| Hot and cold water connections (pipe size) | mm | – |
| Heat exchanger material | Stainless/Aluminimum | Stainless Steel |
| Boiler lift weight (Dry boiler) | kg | 37.5 |
| NOx class | 5 | |
| NOx (En 15502-2-1) | mg/kWh | 30 |
| ErP efficiency | % | 94 |
| ErP decibel rating (sound power) | dBa | 43 |
| Maximum horizontal flue length 60/100 | m | 5.5 |
| Maximum vertical flue length 60/100 | m | 8 |
| Maximum horizontal flue length 80/125 | m | 32 |
| Maximum vertical flue length | m | 34 |
Gas regular boilers

Regular
ecoTEC plus Open Vent
Also, we compare space and hot-water requirements for your Vaillant boiler installation. The ecoTEC plus open-vent family provides 12, 15, 18, 24, 30 and 35kW options. In addition, a rear flue option and compact footprint help when planning a traditional-system replacement.
Compare model specifications
| Technical data | Unit of measure | ecoTEC plus 412 | ecoTEC plus 415 | ecoTEC plus 418 | ecoTEC plus 424 | ecoTEC plus 424 LPG | ecoTEC plus 430 | ecoTEC plus 435 |
|---|---|---|---|---|---|---|---|---|
| Boiler type | open vent | open vent | open vent | open vent | open vent | open vent | open vent | |
| Signature model output | 12kW | 15kW | 18kW | 24kW | 24kW | 30kW | 35kW | |
| Article number | 0010021220 | 0010021221 | 0010021222 | 0010021223 | 0020231355 | 0010021224 | ||
| Gas Council number | 41-694-13 | 41-694-14 | 41-694-15 | 41-694-16 | 41-694-18 | 41-694-17 | 41-044-76 | |
| Boiler dimensions (HxWxD) | mm | 602 x 375 x 320 | 602 x 375 x 320 | 602 x 375 x 320 | 602 x 375 x 320 | 602 x 375 x 320 | 602 x 375 x 320 | 602 x 375 x 320 |
| Nominal heat output range at 50/30˚C (Condensing mode) | kW | 4.7 – 12.8 | 4.7 – 15.9 | 5.2 – 19.1 | 6.3 – 25.7 | 8 – 25.7 | 7.5 – 31.8 | 7.5 – 37.1 |
| Nominal heat output range at 80/60˚C (Non condensing mode) | kwW | 4.5 – 12.3 | 4.5 – 15.2 | 5 – 18.3 | 6.1 – 24.6 | 7.6 – 24.3 | 7.2 – 30.5 | 7.1 – 35.1 |
| Maximum flow temperature | ˚C | 80 | 80 | 80 | 80 | 80 | 80 | 80 |
| Flow temperature range | ˚C | 10 – 80 | 10 – 80 | 10 – 80 | 10 – 80 | 10 – 80 | 10 – 80 | 10 – 80 |
| Flow temperature factory setting | ˚C | 75 | 75 | 75 | 75 | 75 | 75 | 75 |
| Approximate condensate volume at 50/30˚C | litres/hr | 1.23 | 1.53 | 1.84 | 2.47 | 2.47 | 3.06 | 3.57 |
| Modulation (max/min) | 1 : X | 1:4 | 1:4 | 1:5 | 1:4.9 | 1:3.9 | 1:4.9 | 1:4.9 |
| Maximum heat output for water generation | kW | 18 | 18 | 25.2 | 30 | 30 | 35 | 35.1 |
| Lowest water pressure to operate boiler | bar | – | – | – | – | – | – | – |
| Lowest water flow for operation | l/min | – | – | – | – | – | – | – |
| Lowest water pressure for maximum flow rate | bar | – | – | – | – | – | – | – |
| Domestic hot water flow rate (at DT = Δ35K) * | l/min | – | – | – | – | – | – | – |
| Hot water output temperature range | ˚C | – | – | – | – | – | – | – |
| NOx class | 6 | 6 | 6 | 6 | 6 | 6 | 6 | |
| NOx (En 15502-2-1) | mg/kWh | 32 | 33 | 39 | 39 | 35 | 40 | 32 |
| ErP efficiency | % | 94 | 94 | 94 | 94 | 94 | 94 | 93 |
| ErP decibel rating (sound power) | dBa | 45 | 48 | 51 | 52 | 49 | 55 | 53 |
| Maximum horizontal flue length 60/100 | m | 10 | 10 | 10 | 10 | 0.7 | 10 | 10 |
| Maximum vertial flue length | m | 10 | 10 | 10 | 10 | – | 10 | 10 |
| Maximum horizontal flue length 80/125 | m | 25 | 25 | 25 | 25 | – | 25 | 25 |
| Maximum vertical flue length 80/125 | m | 25 | 25 | 25 | 25 | – | 25 | 25 |
| Gas inlet connection (pipe size) | mm | 15 | ||||||
| Heating flow and return connections (pipe size) | mm | 22 | ||||||
| Heat exchanger material | Stainless/ Aluminium | Aluminium | ||||||
| Boiler lift weight (dry boiler) | kg | 23.0 | ||||||
| Maximum horizontal flue length 60/100 | m | 10 | 0.7* | 10 | ||||
| Rear flue options | Yes/No | Yes | No | Yes | ||||
| Permissible flue classifications | C13, C33, C43, C53 (LPG option is only suitable for C13 classification and can only be fitted with the top mounted horizontal flue supplied) |
Compare figures carefully, because manufacturers publish different units and test conditions. For example, hot-water flow at a 35°C temperature rise differs from a figure measured at 40°C. In addition, ErP efficiency and seasonal efficiency to DIN use different test methods. Therefore, we explain the relevant figures before matching the exact model to your quotation.
What matters when choosing Vaillant boilers?
First, we calculate your home’s heating requirement, because radiator numbers alone cannot tell us the right boiler output. In addition, we compare the boiler’s minimum output so it can respond to smaller heating demands.
Next, we assess hot water, because the available water supply and temperature rise affect a combi’s flow at your taps. By contrast, a cylinder-based system needs the right storage capacity and recovery. Therefore, we discuss your showers, baths and daily routine together.
Also, we check the installation space, service access, flue route and controls. Although case dimensions are useful, the installation needs working room around the appliance too. As a result, your quotation covers a complete, practical boiler replacement.

Choose the right Vaillant boiler type

Combi boilers
A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.
Discuss your boiler type →
System boilers
A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.
Discuss your boiler type →
Regular boilers
A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.
Discuss your boiler type →Natural gas and LPG boiler installations
For natural gas, we check the existing supply, boiler position and heating system. In addition, Vaillant offers LPG options within the appropriate ranges. We specify the correct model and fuel setup for your off-mains home.
For example, an LPG version or conversion applies to particular models rather than every boiler in a family. Therefore, our survey confirms the exact appliance and configuration before we quote. Our Gas Safe registered team completes the installation and commissioning.
Your Vaillant boiler installation, step by step
Survey your home
First, we discuss your rooms, heating and hot-water use. Also, we inspect the boiler, supply, radiators and controls, so your Vaillant boiler installation has a clear starting point.
Compare the options
Next, we explain suitable ranges, outputs and controls. Therefore, your quotation sets out the chosen boiler, fitting work and any system changes. You can then decide with a clear picture of the work.
Prepare and fit carefully
Then, we prepare the heating system and address cleaning and filtration. In addition, we fit the boiler, flue, pipework and controls with attention to service access and the finished appearance.
Commission and hand over
Finally, we test and commission the appliance, complete the records and explain the settings. Also, we show you the heating schedule and everyday controls, then help you arrange ongoing servicing.
INDEPENDENTLY REVIEWED
Heating work backed by hundreds of five-star reviews
For example, customers repeatedly mention punctual engineers, tidy workmanship and clear advice before, during and after their heating project.
The gas-boiler service was completed efficiently and the certificate arrived by email almost immediately.
An older-property boiler upgrade finished on time, with tidy workmanship, punctual attendance and a flexible approach.
A last-minute boiler service was arranged quickly and completed efficiently by a team the customer readily recommends.
Review totals checked September 2026. Read the complete independent feedback on Google and Which? Trusted Traders.
Vaillant boiler questions
Can Oxyplumb install a Vaillant boiler?
We install Vaillant boilers across Oxfordshire, including straightforward replacements and wider heating upgrades. First, tell us about your current appliance so we can understand what you want to improve.
Which boiler output should I choose?
First, consider your home’s heating demand and hot-water use. Therefore, we assess the property, water supply and existing system before recommending an output. After all, the largest model is not automatically the right choice.
Can you replace a boiler from another brand?
Your existing boiler can be from another brand, because we plan the replacement around your heating system. First, we inspect the system, explain the options and quote for the work needed to fit your chosen Vaillant replacement.
Do you service and repair other boiler makes?
Our maintenance work also covers a broad range of boiler manufacturers, including older and less familiar makes. First, tell us your boiler’s make, model and fuel, so we can arrange the right engineer.
Local Vaillant boiler installation and ongoing care
For example, our team covers Faringdon, Wantage, Abingdon, Stanford in the Vale, Oxford, Bampton, Clanfield, Witney, Cumnor, Carterton, Uffington and Kingston Bagpuize. Choose your area to find its dedicated installation, servicing and repair pages.
Also, we maintain and repair boilers from a broad range of manufacturers. Explore our boiler servicing and boiler repair services, or compare our other manufacturer guides below.
Ready to choose your new Vaillant boiler?
First, tell Oxyplumb about your home and the work you have in mind. Then, we will help you choose the right boiler and provide a clear installation quotation.





OFTEC and Gas Safe registered.


















Worcester Bosch
Grant oil boilers