Ideal boiler installation · Oxfordshire

Ideal boiler installation in Oxfordshire

Explore Ideal Logic, Logic Max, Logic+ and Vogue Max boilers. Oxyplumb helps you choose between combi, system and heat-only arrangements for a well-planned new boiler, replacement or heating upgrade.

IdealGas Safe registered — registration 622923Which? Trusted Trader
Ideal boilers for a new boiler installation

Ideal boilers, chosen around your home

For Ideal boiler installation in Oxfordshire, we bring the boiler, controls and existing system into one clear plan. First, we look at your rooms and bathroom use. Then, we explain the ranges and appropriate outputs, so you can make an informed choice.

Explore the Ideal boiler range

First, compare the Ideal boiler ranges below, using the images and key facts alongside each description. Then, open the model specifications to see the published figures, or ask our team to explain the choices for your home.

Gas combi and storage boilers

Ideal Logic MAX Combi boiler

Combi

Logic MAX Combi

First, we check how this range would suit your Ideal boiler installation. A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.

DHW flow rate l/min 35ºC9.9 · 12.4 · 14.5
DHW output (kW) max24.2 · 30.3 · 35.3
Seasonal space heating efficiency classA · A · A
Compare model specifications
LOGIC MAX COMBI MODELS243035
Weight (Packaged) kg32.83333
Max Installation weight kg28.528.628.6
CH Output(kW) min/max mean 70ºC4.8-24.26.1-24.27.1-24.2
CH Output(kW) min/max mean 40ºC5.1-25.66.4-25.67.5-25.6
DHW output (kW) max24.230.335.3
DHW flow rate l/min 35ºC9.912.414.5
SEDBUK rating (2005)%91.191.191.1
SEDBUK rating (2009/2012)%89.689.689.6
NOx ClassificationClass 6Class 6Class 6
LPG conversionYesYesYes
Max Horizontal flue9m8m6m
Max Vertical Flue7.7m7.5m7.5m
Seasonal space heating efficiency classAAA
Seasonal space heating energy efficiency µs %949494
Sound power level indoors LWA dB(A)504646
Water heating energy efficiency classAAA

Ideal range information

Discuss this range →
Logic Combi ESP1 boiler

Combi

Logic Combi ESP1

Also, we compare space and hot-water requirements for your Ideal boiler installation. A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.

DHW output (kW) max24.2 · 30.3 · 35.3
Seasonal space heating efficiency classA · A · A
Compare model specifications
BOILER MODEL243035
Weight (packaged) kg33.733.833.9
Max installation weight kg28.929.029.1
CH Output (kW) min/max mean 70°C4.8 – 24.26.1 – 24.27.1 – 24.2
CH Output (kW) min/max mean 40°C5.1 – 25.66.4 – 25.67.5 – 25.6
DHW output (kW) max24.230.335.3
SEDBUK rating (2005) %91.191.191.1
SEDBUK rating (2009/2012) %89.689.689.6
NOx classificationCLASS 6CLASS 6CLASS 6
Convert to LPGNoYesYes
Max horizontal flue*9m9m9m
Max vertical flue*7.5m7.5m7.5m
Powered vertical flue*22m22m22m
Condensing boilerYesYesYes
Seasonal space heating efficiency classAAA
Rated heat output kW242424
Seasonal space heating energy efficiency ŋs %949494
Sound power level, indoors LWA dB484644
Water heating energy efficiency classAAA
PCDB Numbers – Natural Gas017955017956017929
PCDB Numbers – Propane (Conversion Kit)018067018060

Ideal range information

Discuss this range →
Ideal Logic+ Combi boiler

Combi

Logic+ Combi

Before your Ideal boiler installation, we assess the existing system and recommend a suitable model. A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.

DHW flow rate I/min. 35°C rise9.9 · 12.4 · 14.5
DHW output (kW) max24.2 · 30.3 · 35.3
Seasonal space heating efficiency classA · A · A
Compare model specifications
C24C30C35
Weight (packaged) kg34.034.134.2
Max installation weight kg29.229.329.4
CH output (kW) min/max mean 70°C4.8 – 24.26.1 – 24.27.1 – 24.2
CH output (kW) min/max mean 40°C5.1 – 25.66.4 – 25.67.5 – 25.6
DHW output (kW) max24.230.335.3
DHW flow rate I/min. 35°C rise9.912.414.5
SEDBUK rating (2005) %91.191.191.1
SEDBUK rating (2009/2012) %89.689.689.6
Nox classificationCLASS 6CLASS 6CLASS 6
Convert to LPGYesYesNo
Max horizontal flue9m8m6m
Max vertical flue7.5m7.5m7.5m
Powered vertical flue*22m22m22m
Condensing boilerYesYesYes
Seasonal space heating efficiency classAAA
Rated heat output kW242424
Seasonal space heating energy efficiency ŋs %949494
Sound power level, indoors Lwa dB484644
Water heating energy efficiency classAAA

Ideal range information

Discuss this range →
Vogue MAX Combi boiler

Combi

Vogue MAX Combi

First, we check how this range would suit your Ideal boiler installation. A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.

DHW flow rate I/min. 35°C rise10.6 · 13.1 · 16.4
DHW output (kW) max26 · 32 · 40
Seasonal space heating energy efficiency ŋs%92.7 · 93.1 · 93
Compare model specifications
COMBI C26COMBI C32COMBI C40
Weight (packaged) kg41.141.443.4
Max installation weight kg32.433.835.4
CH output (kW) min/max @ 70°C3.7 – 18.04.6 – 26.05.7 – 32.0
CH output (kW) min/max @ 40°C4.0 – 19.34.9 – 27.96.1 – 34.3
DHW output (kW) max263240
DHW flow rate I/min. 35°C rise10.613.116.4
SEDBUK rating (2005) %9191.191
SEDBUK rating (2009/2012) %89.189.289.1
NOx classificationCLASS 6CLASS 6CLASS 6
Convertible to LPGYesYesYes
Max horizontal flue10m8m8m
Max vertical flue10m10m10m
Condensing boilerYesYesYes
Seasonal space heating energy efficiency ŋs%92.793.193
Sound powr level, indoors Lwa dB475049
Water heating energy efficiency classAAA

Ideal range information

Discuss this range →

Gas regular boilers

Logic+ Heat boiler

Regular

Logic+ Heat

Also, we compare space and hot-water requirements for your Ideal boiler installation. A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.

DHW flow rate l/min. 35°C risen/a · n/a · n/a · n/a · n/a
DHW output (kW) maxn/a · n/a · n/a · n/a · n/a
Seasonal space heating efficiency classA · A · A · A · A
Compare model specifications
BOILER MODELH12H15H18H24H30
Weight (packaged) kg26.226.226.226.126.2
Max installation weight kg22.722.722.722.722.7
CH output (kW) min/max mean 70°C4.8 – 12.04.8 – 15.04.8 – 18.04.8 -24.26.1 – 30.3
CH output (kW) min/max mean 40°C5.1 – 13.05.1 – 15.95.1 – 19.15.1 – 25.66.4 – 31.0
DHW output (kW) maxn/an/an/an/an/a
DHW flow rate l/min. 35°C risen/an/an/an/an/a
SEDUK rating (2005) %91.291.1919191.1
SEDUK rating (2009/2012) %89.489.389.289.589.6
NOx classificationCLASS 6CLASS 6CLASS 6CLASS 6CLASS 6
Convert to LPGNoNoNoNoYes
Max horizontal flue9m9m9m9m8m
Max vertical flue7.5m7.5m7.5m97.5mm7.5m
Powered vertical flue*22m22m22m22m22m
Condensing boilerYesYesYesYesYes
Direct rear flue kit (55/80)YesYesYesYesYes
Seasonal space heating efficiency classAAAAA
Rated heat output kW1215182430
Seasonal space heating energy efficiency ηs %9393939493
Sound power level, indoors LWA dB3638414749
Water heating energy efficiency classn/an/an/an/an/a

Ideal range information

Discuss this range →
Ideal Logic MAX Heat boiler

Regular

Logic MAX Heat

Before your Ideal boiler installation, we assess the existing system and recommend a suitable model. A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.

Seasonal space heating efficiency classA · A · A · A · A
Compare model specifications
LOGIC MAX HEAT MODELS1215182430
LOGIC MAX HEAT² MODELS2727272727
Max Installation weight kg21.921.921.921.921.9
CH Output(kW) min/max mean 70ºC4.8-12.04.8-15.04.8-18.04.8-24.26.1-30.3
CH Output(kW) min/max mean 40ºC5.1-13.05.1-15.95.1-19.15.1-25.66.4-31.0
SEDBUK rating (2005)%91.191.291.191.291.1
SEDBUK rating (2009/2012)%89.489.489.789.789.6
NOx ClassificationClass 6Class 6Class 6Class 6Class 6
LPG conversionNoN0YesYesYes
Max Horizontal flue9m9m9m9m9m
Max Vertical Flue7.7m7.5m7.5m7.5m7.5m
Seasonal space heating efficiency classAAAAA
Seasonal space heating energy efficiency µs %9393949493
Sound power level indoors LWA Db3642445050
Sound power level, indoors LWA dB(A)3638414749

Ideal range information

Discuss this range →

Gas system boilers

Ideal Logic+ System boiler

System

Logic+ System

First, we check how this range would suit your Ideal boiler installation. A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.

DHW output (kW) maxn/a · n/a · n/a · n/a
Seasonal space heating efficiency classA · A · A · A
Compare model specifications
BOILER MODELS15S18S24S30
Weight (packaged) kg31.631.631.631.6
Max installation weight kg26.226.226.226.2
CH output (kW) min/max @ 70°C4.8 – 15.04.8 – 18.04.8 – 24.26.1 – 30.3
CH output (kW) min/max @ 40°C5.1 – 15.95.1 – 19.15.1 – 25.66.4 – 31.0
DHW output (kW) maxn/an/an/an/a
DHW flow rating I/min. 35°C risen/an/an/an/a
SEDBUK rating (2005) %91.291.191.291.1
SEDBUK rating (2009/2012) %89.489.789.789.6
NOx classificationCLASS 6CLASS 6CLASS 6CLASS 6
Convert to LPGNoNoNoYes
Max horizontal flue9m9m9m8m
Max vertical flue7.5m7.5m7.5m7.5m
Powered vertical flue22m22m22m22m
Condensing boilerYesYesYesYes
Seasonal space heating efficiency classAAAA
Related heat output kW15182430
Seasonal space heating energy efficiency ŋs %93939493
Sound power level, indoors Lwa dB44464848
Water heating energy efficiency classn/an/an/an/a

Ideal range information

Discuss this range →
Vogue MAX System boiler

System

Vogue MAX System

Also, we compare space and hot-water requirements for your Ideal boiler installation. A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.

DHW output (kW) maxn/a · n/a · n/a · n/a
Seasonal space heating efficiency classA · A · A · A
Compare model specifications
SYSTEM S15SYSTEM S18SYSTEM S26SYSTEM S32
Weight (packaged) kg3838.840.242.2
Max installation weight kg30.731.532.934.3
CH output (kW) min/max @ 70°C3.0 – 15.03.6 – 18.05.2 – 26.06.4 – 32.0
CH output (kW) min/max @ 40°C3.2 – 16.23.9 – 19.35.6 – 27.96.8 – 34.3
DHW output (kW) maxn/an/an/an/a
DHW flow rating I/min. 35°C risen/an/an/an/a
SEDBUK rating (2005) %9191.191.191.1
SEDBUK rating (2009/2012) %88.989.389.389.3
NOx classificationCLASS 6CLASS 6CLASS 6CLASS 6
Convertible to LPGYesYesYesYes
Max horizontal flue10m10m10m8m
Max vertical flue10m10m10m10m
Condensing boilerYesYesYesYes
Seasonal space heating efficiency classAAAA
Related heat output Kw15182632
Seasonal space heating efficiency ŋs %92.493.293.193.2
Sound power level, indoors Lwa dB50525250
Water heating energy efficiency classn/an/an/an/a

Ideal range information

Discuss this range →
Ideal Logic MAX System boiler

System

Logic MAX System

Before your Ideal boiler installation, we assess the existing system and recommend a suitable model. A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.

Seasonal space heating efficiency classA · A · A · A
Compare model specifications
Logic Max System Models15182430
Weight (Packaged) kg31.331.331.331.3
Weight (Packaged) kg27.327.327.327.3
CH Output(kW) min/max mean 70ºC4.8-15.04.8-18.04.8-24.26.1-30.3
CH Output(kW) min/max mean 40ºC5.1-15.95.1-19.15.1-25.66.4-31.0
SEDBUK rating (2005)%91.291.191.291.1
SEDBUK rating (2009/2012)%89.489.789.789.6
NOx ClassificationClass 6Class 6Class 6Class 6
LPG conversionNoYesNoYes
Max Horizontal flue9m9m9m9m
Max Vertical Flue7.7m7.5m7.5m7.5m
Seasonal space heating efficiency classAAAA
Seasonal space heating energy efficiency µs %93939493
Sound power level indoors LWA dB(A)42445050

Ideal range information

Discuss this range →

Compare figures carefully, because manufacturers publish different units and test conditions. For example, hot-water flow at a 35°C temperature rise differs from a figure measured at 40°C. In addition, ErP efficiency and seasonal efficiency to DIN use different test methods. Therefore, we explain the relevant figures before matching the exact model to your quotation.

What matters when choosing Ideal boilers?

First, we calculate your home’s heating requirement, because radiator numbers alone cannot tell us the right boiler output. In addition, we compare the boiler’s minimum output so it can respond to smaller heating demands.

Next, we assess hot water, because the available water supply and temperature rise affect a combi’s flow at your taps. By contrast, a cylinder-based system needs the right storage capacity and recovery. Therefore, we discuss your showers, baths and daily routine together.

Also, we check the installation space, service access, flue route and controls. Although case dimensions are useful, the installation needs working room around the appliance too. As a result, your quotation covers a complete, practical boiler replacement.

Ideal boiler installation planned around the home

Choose the right Ideal boiler type

Ideal combi boiler installation

Combi boilers

A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.

Discuss your boiler type →
Ideal system boiler installation

System boilers

A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.

Discuss your boiler type →
Ideal regular boiler installation

Regular boilers

A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.

Discuss your boiler type →

Natural gas and LPG boiler installations

For natural gas, we check the existing supply, boiler position and heating system. In addition, Ideal offers LPG options within the appropriate ranges. We specify the correct model and fuel setup for your off-mains home.

For example, an LPG version or conversion applies to particular models rather than every boiler in a family. Therefore, our survey confirms the exact appliance and configuration before we quote. Our Gas Safe registered team completes the installation and commissioning.

Your Ideal boiler installation, step by step

01

Survey your home

First, we discuss your rooms, heating and hot-water use. Also, we inspect the boiler, supply, radiators and controls, so your Ideal boiler installation has a clear starting point.

02

Compare the options

Next, we explain suitable ranges, outputs and controls. Therefore, your quotation sets out the chosen boiler, fitting work and any system changes. You can then decide with a clear picture of the work.

03

Prepare and fit carefully

Then, we prepare the heating system and address cleaning and filtration. In addition, we fit the boiler, flue, pipework and controls with attention to service access and the finished appearance.

04

Commission and hand over

Finally, we test and commission the appliance, complete the records and explain the settings. Also, we show you the heating schedule and everyday controls, then help you arrange ongoing servicing.

INDEPENDENTLY REVIEWED

Heating work backed by hundreds of five-star reviews

For example, customers repeatedly mention punctual engineers, tidy workmanship and clear advice before, during and after their heating project.

★★★★★
The gas-boiler service was completed efficiently and the certificate arrived by email almost immediately.
F. Gillespie-WalkerGoogle Reviews — Google customer review
★★★★★
An older-property boiler upgrade finished on time, with tidy workmanship, punctual attendance and a flexible approach.
Which? Trusted TradersVerified heating customer, Oxfordshire
★★★★★
A last-minute boiler service was arranged quickly and completed efficiently by a team the customer readily recommends.
K. BrayWhich? Trusted Traders — Verified boiler-service customer

Review totals checked September 2026. Read the complete independent feedback on Google and Which? Trusted Traders.

Ideal boiler questions

Can Oxyplumb install a Ideal boiler?

We install Ideal boilers across Oxfordshire, including straightforward replacements and wider heating upgrades. First, tell us about your current appliance so we can understand what you want to improve.

Which boiler output should I choose?

First, consider your home’s heating demand and hot-water use. Therefore, we assess the property, water supply and existing system before recommending an output. After all, the largest model is not automatically the right choice.

Can you replace a boiler from another brand?

Your existing boiler can be from another brand, because we plan the replacement around your heating system. First, we inspect the system, explain the options and quote for the work needed to fit your chosen Ideal replacement.

Do you service and repair other boiler makes?

Our maintenance work also covers a broad range of boiler manufacturers, including older and less familiar makes. First, tell us your boiler’s make, model and fuel, so we can arrange the right engineer.

Local Ideal boiler installation and ongoing care

For example, our team covers Faringdon, Wantage, Abingdon, Stanford in the Vale, Oxford, Bampton, Clanfield, Witney, Cumnor, Carterton, Uffington and Kingston Bagpuize. Choose your area to find its dedicated installation, servicing and repair pages.

Also, we maintain and repair boilers from a broad range of manufacturers. Explore our boiler servicing and boiler repair services, or compare our other manufacturer guides below.

Ready to choose your new Ideal boiler?

First, tell Oxyplumb about your home and the work you have in mind. Then, we will help you choose the right boiler and provide a clear installation quotation.