Ideal boiler installation · Oxfordshire
Ideal boiler installation in Oxfordshire
Explore Ideal Logic, Logic Max, Logic+ and Vogue Max boilers. Oxyplumb helps you choose between combi, system and heat-only arrangements for a well-planned new boiler, replacement or heating upgrade.



Ideal boilers, chosen around your home
For Ideal boiler installation in Oxfordshire, we bring the boiler, controls and existing system into one clear plan. First, we look at your rooms and bathroom use. Then, we explain the ranges and appropriate outputs, so you can make an informed choice.
Explore the Ideal boiler range
First, compare the Ideal boiler ranges below, using the images and key facts alongside each description. Then, open the model specifications to see the published figures, or ask our team to explain the choices for your home.
Gas combi and storage boilers

Combi
Logic MAX Combi
First, we check how this range would suit your Ideal boiler installation. A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.
Compare model specifications
| LOGIC MAX COMBI MODELS | 24 | 30 | 35 |
|---|---|---|---|
| Weight (Packaged) kg | 32.8 | 33 | 33 |
| Max Installation weight kg | 28.5 | 28.6 | 28.6 |
| CH Output(kW) min/max mean 70ºC | 4.8-24.2 | 6.1-24.2 | 7.1-24.2 |
| CH Output(kW) min/max mean 40ºC | 5.1-25.6 | 6.4-25.6 | 7.5-25.6 |
| DHW output (kW) max | 24.2 | 30.3 | 35.3 |
| DHW flow rate l/min 35ºC | 9.9 | 12.4 | 14.5 |
| SEDBUK rating (2005)% | 91.1 | 91.1 | 91.1 |
| SEDBUK rating (2009/2012)% | 89.6 | 89.6 | 89.6 |
| NOx Classification | Class 6 | Class 6 | Class 6 |
| LPG conversion | Yes | Yes | Yes |
| Max Horizontal flue | 9m | 8m | 6m |
| Max Vertical Flue | 7.7m | 7.5m | 7.5m |
| Seasonal space heating efficiency class | A | A | A |
| Seasonal space heating energy efficiency µs % | 94 | 94 | 94 |
| Sound power level indoors LWA dB(A) | 50 | 46 | 46 |
| Water heating energy efficiency class | A | A | A |

Combi
Logic Combi ESP1
Also, we compare space and hot-water requirements for your Ideal boiler installation. A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.
Compare model specifications
| BOILER MODEL | 24 | 30 | 35 |
|---|---|---|---|
| Weight (packaged) kg | 33.7 | 33.8 | 33.9 |
| Max installation weight kg | 28.9 | 29.0 | 29.1 |
| CH Output (kW) min/max mean 70°C | 4.8 – 24.2 | 6.1 – 24.2 | 7.1 – 24.2 |
| CH Output (kW) min/max mean 40°C | 5.1 – 25.6 | 6.4 – 25.6 | 7.5 – 25.6 |
| DHW output (kW) max | 24.2 | 30.3 | 35.3 |
| SEDBUK rating (2005) % | 91.1 | 91.1 | 91.1 |
| SEDBUK rating (2009/2012) % | 89.6 | 89.6 | 89.6 |
| NOx classification | CLASS 6 | CLASS 6 | CLASS 6 |
| Convert to LPG | No | Yes | Yes |
| Max horizontal flue* | 9m | 9m | 9m |
| Max vertical flue* | 7.5m | 7.5m | 7.5m |
| Powered vertical flue* | 22m | 22m | 22m |
| Condensing boiler | Yes | Yes | Yes |
| Seasonal space heating efficiency class | A | A | A |
| Rated heat output kW | 24 | 24 | 24 |
| Seasonal space heating energy efficiency ŋs % | 94 | 94 | 94 |
| Sound power level, indoors LWA dB | 48 | 46 | 44 |
| Water heating energy efficiency class | A | A | A |
| PCDB Numbers – Natural Gas | 017955 | 017956 | 017929 |
| PCDB Numbers – Propane (Conversion Kit) | 018067 | 018060 |

Combi
Logic+ Combi
Before your Ideal boiler installation, we assess the existing system and recommend a suitable model. A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.
Compare model specifications
| C24 | C30 | C35 | |
|---|---|---|---|
| Weight (packaged) kg | 34.0 | 34.1 | 34.2 |
| Max installation weight kg | 29.2 | 29.3 | 29.4 |
| CH output (kW) min/max mean 70°C | 4.8 – 24.2 | 6.1 – 24.2 | 7.1 – 24.2 |
| CH output (kW) min/max mean 40°C | 5.1 – 25.6 | 6.4 – 25.6 | 7.5 – 25.6 |
| DHW output (kW) max | 24.2 | 30.3 | 35.3 |
| DHW flow rate I/min. 35°C rise | 9.9 | 12.4 | 14.5 |
| SEDBUK rating (2005) % | 91.1 | 91.1 | 91.1 |
| SEDBUK rating (2009/2012) % | 89.6 | 89.6 | 89.6 |
| Nox classification | CLASS 6 | CLASS 6 | CLASS 6 |
| Convert to LPG | Yes | Yes | No |
| Max horizontal flue | 9m | 8m | 6m |
| Max vertical flue | 7.5m | 7.5m | 7.5m |
| Powered vertical flue* | 22m | 22m | 22m |
| Condensing boiler | Yes | Yes | Yes |
| Seasonal space heating efficiency class | A | A | A |
| Rated heat output kW | 24 | 24 | 24 |
| Seasonal space heating energy efficiency ŋs % | 94 | 94 | 94 |
| Sound power level, indoors Lwa dB | 48 | 46 | 44 |
| Water heating energy efficiency class | A | A | A |

Combi
Vogue MAX Combi
First, we check how this range would suit your Ideal boiler installation. A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.
Compare model specifications
| COMBI C26 | COMBI C32 | COMBI C40 | |
|---|---|---|---|
| Weight (packaged) kg | 41.1 | 41.4 | 43.4 |
| Max installation weight kg | 32.4 | 33.8 | 35.4 |
| CH output (kW) min/max @ 70°C | 3.7 – 18.0 | 4.6 – 26.0 | 5.7 – 32.0 |
| CH output (kW) min/max @ 40°C | 4.0 – 19.3 | 4.9 – 27.9 | 6.1 – 34.3 |
| DHW output (kW) max | 26 | 32 | 40 |
| DHW flow rate I/min. 35°C rise | 10.6 | 13.1 | 16.4 |
| SEDBUK rating (2005) % | 91 | 91.1 | 91 |
| SEDBUK rating (2009/2012) % | 89.1 | 89.2 | 89.1 |
| NOx classification | CLASS 6 | CLASS 6 | CLASS 6 |
| Convertible to LPG | Yes | Yes | Yes |
| Max horizontal flue | 10m | 8m | 8m |
| Max vertical flue | 10m | 10m | 10m |
| Condensing boiler | Yes | Yes | Yes |
| Seasonal space heating energy efficiency ŋs% | 92.7 | 93.1 | 93 |
| Sound powr level, indoors Lwa dB | 47 | 50 | 49 |
| Water heating energy efficiency class | A | A | A |
Gas regular boilers

Regular
Logic+ Heat
Also, we compare space and hot-water requirements for your Ideal boiler installation. A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.
Compare model specifications
| BOILER MODEL | H12 | H15 | H18 | H24 | H30 |
|---|---|---|---|---|---|
| Weight (packaged) kg | 26.2 | 26.2 | 26.2 | 26.1 | 26.2 |
| Max installation weight kg | 22.7 | 22.7 | 22.7 | 22.7 | 22.7 |
| CH output (kW) min/max mean 70°C | 4.8 – 12.0 | 4.8 – 15.0 | 4.8 – 18.0 | 4.8 -24.2 | 6.1 – 30.3 |
| CH output (kW) min/max mean 40°C | 5.1 – 13.0 | 5.1 – 15.9 | 5.1 – 19.1 | 5.1 – 25.6 | 6.4 – 31.0 |
| DHW output (kW) max | n/a | n/a | n/a | n/a | n/a |
| DHW flow rate l/min. 35°C rise | n/a | n/a | n/a | n/a | n/a |
| SEDUK rating (2005) % | 91.2 | 91.1 | 91 | 91 | 91.1 |
| SEDUK rating (2009/2012) % | 89.4 | 89.3 | 89.2 | 89.5 | 89.6 |
| NOx classification | CLASS 6 | CLASS 6 | CLASS 6 | CLASS 6 | CLASS 6 |
| Convert to LPG | No | No | No | No | Yes |
| Max horizontal flue | 9m | 9m | 9m | 9m | 8m |
| Max vertical flue | 7.5m | 7.5m | 7.5m | 97.5mm | 7.5m |
| Powered vertical flue* | 22m | 22m | 22m | 22m | 22m |
| Condensing boiler | Yes | Yes | Yes | Yes | Yes |
| Direct rear flue kit (55/80) | Yes | Yes | Yes | Yes | Yes |
| Seasonal space heating efficiency class | A | A | A | A | A |
| Rated heat output kW | 12 | 15 | 18 | 24 | 30 |
| Seasonal space heating energy efficiency ηs % | 93 | 93 | 93 | 94 | 93 |
| Sound power level, indoors LWA dB | 36 | 38 | 41 | 47 | 49 |
| Water heating energy efficiency class | n/a | n/a | n/a | n/a | n/a |

Regular
Logic MAX Heat
Before your Ideal boiler installation, we assess the existing system and recommend a suitable model. A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.
Compare model specifications
| LOGIC MAX HEAT MODELS | 12 | 15 | 18 | 24 | 30 |
|---|---|---|---|---|---|
| LOGIC MAX HEAT² MODELS | 27 | 27 | 27 | 27 | 27 |
| Max Installation weight kg | 21.9 | 21.9 | 21.9 | 21.9 | 21.9 |
| CH Output(kW) min/max mean 70ºC | 4.8-12.0 | 4.8-15.0 | 4.8-18.0 | 4.8-24.2 | 6.1-30.3 |
| CH Output(kW) min/max mean 40ºC | 5.1-13.0 | 5.1-15.9 | 5.1-19.1 | 5.1-25.6 | 6.4-31.0 |
| SEDBUK rating (2005)% | 91.1 | 91.2 | 91.1 | 91.2 | 91.1 |
| SEDBUK rating (2009/2012)% | 89.4 | 89.4 | 89.7 | 89.7 | 89.6 |
| NOx Classification | Class 6 | Class 6 | Class 6 | Class 6 | Class 6 |
| LPG conversion | No | N0 | Yes | Yes | Yes |
| Max Horizontal flue | 9m | 9m | 9m | 9m | 9m |
| Max Vertical Flue | 7.7m | 7.5m | 7.5m | 7.5m | 7.5m |
| Seasonal space heating efficiency class | A | A | A | A | A |
| Seasonal space heating energy efficiency µs % | 93 | 93 | 94 | 94 | 93 |
| Sound power level indoors LWA Db | 36 | 42 | 44 | 50 | 50 |
| Sound power level, indoors LWA dB(A) | 36 | 38 | 41 | 47 | 49 |
Gas system boilers

System
Logic+ System
First, we check how this range would suit your Ideal boiler installation. A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.
Compare model specifications
| BOILER MODEL | S15 | S18 | S24 | S30 |
|---|---|---|---|---|
| Weight (packaged) kg | 31.6 | 31.6 | 31.6 | 31.6 |
| Max installation weight kg | 26.2 | 26.2 | 26.2 | 26.2 |
| CH output (kW) min/max @ 70°C | 4.8 – 15.0 | 4.8 – 18.0 | 4.8 – 24.2 | 6.1 – 30.3 |
| CH output (kW) min/max @ 40°C | 5.1 – 15.9 | 5.1 – 19.1 | 5.1 – 25.6 | 6.4 – 31.0 |
| DHW output (kW) max | n/a | n/a | n/a | n/a |
| DHW flow rating I/min. 35°C rise | n/a | n/a | n/a | n/a |
| SEDBUK rating (2005) % | 91.2 | 91.1 | 91.2 | 91.1 |
| SEDBUK rating (2009/2012) % | 89.4 | 89.7 | 89.7 | 89.6 |
| NOx classification | CLASS 6 | CLASS 6 | CLASS 6 | CLASS 6 |
| Convert to LPG | No | No | No | Yes |
| Max horizontal flue | 9m | 9m | 9m | 8m |
| Max vertical flue | 7.5m | 7.5m | 7.5m | 7.5m |
| Powered vertical flue | 22m | 22m | 22m | 22m |
| Condensing boiler | Yes | Yes | Yes | Yes |
| Seasonal space heating efficiency class | A | A | A | A |
| Related heat output kW | 15 | 18 | 24 | 30 |
| Seasonal space heating energy efficiency ŋs % | 93 | 93 | 94 | 93 |
| Sound power level, indoors Lwa dB | 44 | 46 | 48 | 48 |
| Water heating energy efficiency class | n/a | n/a | n/a | n/a |

System
Vogue MAX System
Also, we compare space and hot-water requirements for your Ideal boiler installation. A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.
Compare model specifications
| SYSTEM S15 | SYSTEM S18 | SYSTEM S26 | SYSTEM S32 | |
|---|---|---|---|---|
| Weight (packaged) kg | 38 | 38.8 | 40.2 | 42.2 |
| Max installation weight kg | 30.7 | 31.5 | 32.9 | 34.3 |
| CH output (kW) min/max @ 70°C | 3.0 – 15.0 | 3.6 – 18.0 | 5.2 – 26.0 | 6.4 – 32.0 |
| CH output (kW) min/max @ 40°C | 3.2 – 16.2 | 3.9 – 19.3 | 5.6 – 27.9 | 6.8 – 34.3 |
| DHW output (kW) max | n/a | n/a | n/a | n/a |
| DHW flow rating I/min. 35°C rise | n/a | n/a | n/a | n/a |
| SEDBUK rating (2005) % | 91 | 91.1 | 91.1 | 91.1 |
| SEDBUK rating (2009/2012) % | 88.9 | 89.3 | 89.3 | 89.3 |
| NOx classification | CLASS 6 | CLASS 6 | CLASS 6 | CLASS 6 |
| Convertible to LPG | Yes | Yes | Yes | Yes |
| Max horizontal flue | 10m | 10m | 10m | 8m |
| Max vertical flue | 10m | 10m | 10m | 10m |
| Condensing boiler | Yes | Yes | Yes | Yes |
| Seasonal space heating efficiency class | A | A | A | A |
| Related heat output Kw | 15 | 18 | 26 | 32 |
| Seasonal space heating efficiency ŋs % | 92.4 | 93.2 | 93.1 | 93.2 |
| Sound power level, indoors Lwa dB | 50 | 52 | 52 | 50 |
| Water heating energy efficiency class | n/a | n/a | n/a | n/a |

System
Logic MAX System
Before your Ideal boiler installation, we assess the existing system and recommend a suitable model. A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.
Compare model specifications
| Logic Max System Models | 15 | 18 | 24 | 30 |
|---|---|---|---|---|
| Weight (Packaged) kg | 31.3 | 31.3 | 31.3 | 31.3 |
| Weight (Packaged) kg | 27.3 | 27.3 | 27.3 | 27.3 |
| CH Output(kW) min/max mean 70ºC | 4.8-15.0 | 4.8-18.0 | 4.8-24.2 | 6.1-30.3 |
| CH Output(kW) min/max mean 40ºC | 5.1-15.9 | 5.1-19.1 | 5.1-25.6 | 6.4-31.0 |
| SEDBUK rating (2005)% | 91.2 | 91.1 | 91.2 | 91.1 |
| SEDBUK rating (2009/2012)% | 89.4 | 89.7 | 89.7 | 89.6 |
| NOx Classification | Class 6 | Class 6 | Class 6 | Class 6 |
| LPG conversion | No | Yes | No | Yes |
| Max Horizontal flue | 9m | 9m | 9m | 9m |
| Max Vertical Flue | 7.7m | 7.5m | 7.5m | 7.5m |
| Seasonal space heating efficiency class | A | A | A | A |
| Seasonal space heating energy efficiency µs % | 93 | 93 | 94 | 93 |
| Sound power level indoors LWA dB(A) | 42 | 44 | 50 | 50 |
Compare figures carefully, because manufacturers publish different units and test conditions. For example, hot-water flow at a 35°C temperature rise differs from a figure measured at 40°C. In addition, ErP efficiency and seasonal efficiency to DIN use different test methods. Therefore, we explain the relevant figures before matching the exact model to your quotation.
What matters when choosing Ideal boilers?
First, we calculate your home’s heating requirement, because radiator numbers alone cannot tell us the right boiler output. In addition, we compare the boiler’s minimum output so it can respond to smaller heating demands.
Next, we assess hot water, because the available water supply and temperature rise affect a combi’s flow at your taps. By contrast, a cylinder-based system needs the right storage capacity and recovery. Therefore, we discuss your showers, baths and daily routine together.
Also, we check the installation space, service access, flue route and controls. Although case dimensions are useful, the installation needs working room around the appliance too. As a result, your quotation covers a complete, practical boiler replacement.

Choose the right Ideal boiler type

Combi boilers
A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.
Discuss your boiler type →
System boilers
A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.
Discuss your boiler type →
Regular boilers
A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.
Discuss your boiler type →Natural gas and LPG boiler installations
For natural gas, we check the existing supply, boiler position and heating system. In addition, Ideal offers LPG options within the appropriate ranges. We specify the correct model and fuel setup for your off-mains home.
For example, an LPG version or conversion applies to particular models rather than every boiler in a family. Therefore, our survey confirms the exact appliance and configuration before we quote. Our Gas Safe registered team completes the installation and commissioning.
Your Ideal boiler installation, step by step
Survey your home
First, we discuss your rooms, heating and hot-water use. Also, we inspect the boiler, supply, radiators and controls, so your Ideal boiler installation has a clear starting point.
Compare the options
Next, we explain suitable ranges, outputs and controls. Therefore, your quotation sets out the chosen boiler, fitting work and any system changes. You can then decide with a clear picture of the work.
Prepare and fit carefully
Then, we prepare the heating system and address cleaning and filtration. In addition, we fit the boiler, flue, pipework and controls with attention to service access and the finished appearance.
Commission and hand over
Finally, we test and commission the appliance, complete the records and explain the settings. Also, we show you the heating schedule and everyday controls, then help you arrange ongoing servicing.
INDEPENDENTLY REVIEWED
Heating work backed by hundreds of five-star reviews
For example, customers repeatedly mention punctual engineers, tidy workmanship and clear advice before, during and after their heating project.
The gas-boiler service was completed efficiently and the certificate arrived by email almost immediately.
An older-property boiler upgrade finished on time, with tidy workmanship, punctual attendance and a flexible approach.
A last-minute boiler service was arranged quickly and completed efficiently by a team the customer readily recommends.
Review totals checked September 2026. Read the complete independent feedback on Google and Which? Trusted Traders.
Ideal boiler questions
Can Oxyplumb install a Ideal boiler?
We install Ideal boilers across Oxfordshire, including straightforward replacements and wider heating upgrades. First, tell us about your current appliance so we can understand what you want to improve.
Which boiler output should I choose?
First, consider your home’s heating demand and hot-water use. Therefore, we assess the property, water supply and existing system before recommending an output. After all, the largest model is not automatically the right choice.
Can you replace a boiler from another brand?
Your existing boiler can be from another brand, because we plan the replacement around your heating system. First, we inspect the system, explain the options and quote for the work needed to fit your chosen Ideal replacement.
Do you service and repair other boiler makes?
Our maintenance work also covers a broad range of boiler manufacturers, including older and less familiar makes. First, tell us your boiler’s make, model and fuel, so we can arrange the right engineer.
Local Ideal boiler installation and ongoing care
For example, our team covers Faringdon, Wantage, Abingdon, Stanford in the Vale, Oxford, Bampton, Clanfield, Witney, Cumnor, Carterton, Uffington and Kingston Bagpuize. Choose your area to find its dedicated installation, servicing and repair pages.
Also, we maintain and repair boilers from a broad range of manufacturers. Explore our boiler servicing and boiler repair services, or compare our other manufacturer guides below.
Ready to choose your new Ideal boiler?
First, tell Oxyplumb about your home and the work you have in mind. Then, we will help you choose the right boiler and provide a clear installation quotation.





OFTEC and Gas Safe registered.


















Worcester Bosch
Vaillant
Grant oil boilers