Vaillant boiler installation · Oxfordshire

Vaillant boiler installation in Oxfordshire

Vaillant Advance installers offering new boilers, boiler replacements and heating upgrades. Explore ecoTEC and ecoFIT boilers, then choose a system planned around your home and everyday hot-water needs.

Vaillant Advance InstallerGas Safe registered — registration 622923Which? Trusted Trader
Vaillant boilers for a new boiler installation

Vaillant boilers, chosen around your home

For Vaillant boiler installation in Oxfordshire, talk to Oxyplumb about the whole heating system. First, we check your existing boiler, radiators, water supply and controls. Then, we explain the practical differences between suitable Vaillant models and provide a clear installation quotation.

We are Vaillant Advance installers, offering the maximum 10-year guarantee on our relevant Vaillant installations. Our team takes care of specifying, fitting, commissioning and registering your new boiler.

Explore the Vaillant boiler range

First, compare the Vaillant boiler ranges below, using the images and key facts alongside each description. Then, open the model specifications to see the published figures, or ask our team to explain the choices for your home.

Gas combi and storage boilers

Vaillant ecoTEC pro boiler

Combi

ecoTEC pro

First, we check how this range would suit your Vaillant boiler installation. The ecoTEC pro combi range offers 24, 28 and 30kW models. In addition, aquaCOMFORT pre-heating and a stainless steel heat exchanger support straightforward everyday operation.

Domestic hot water flow rate (at DT = Δ35K) *l/min · 9.6 · 11.1 · 11.1 · 12.3
ErP efficiency% · 93 · 93 · 93 · 93
Nominal heat output range at 50/30˚C (Condensing mode)kW · 5.9 – 24.8 · 5.9 – 25.9 · 6.9 – 25.3 · 6.9 – 25.7
Compare model specifications
Technical dataUnit of measureecoTEC pro 24ecoTEC pro 28ecoTEC pro 28 LPGecoTEC pro 30
Boiler typecombicombicombicombi
Article number0010021836001002183700100218380010016538
Gas Council number47-044-8847-044-8947-044-9047-044-52
Boiler dimensions (HxWxD)mm720 x 440 x 338720 x 440 x 338720 x 440 x 338720 x 440 x 338
Nominal heat output range at 50/30˚C (Condensing mode)kW5.9 – 24.85.9 – 25.96.9 – 25.36.9 – 25.7
Nominal heat output range at 80/60˚C (Non condensing mode)kW5.2 – 23.05.2 – 24.07.2 – 24.06.2 – 24.4
Maximum flow temperature˚C85858585
Flow temperature range˚C30 – 8530 – 8530 – 8530 – 85
Flow temperature factory setting˚C75757575
Approximate condensate volume at 50/30˚Clitres/hr1.91.91.92:5
Modulation (max/min)1 : X1:4.31:51:3.61:3.8
Maximum heat output for water generationkW23.427.227.230
Lowest water pressure to operate boilerbar0.80.80.80.8
Lowest water flow for operationl/min2.02.02.02.0
Lowest water pressure for maximum flow ratebar0.80.80.80.8
Domestic hot water flow rate (at DT = Δ35K) *l/min9.611.111.112.3
Hot water output temperature range˚C35 – 6535 – 6535 – 6535 – 65
Expansion vessel sizelites8888
Gas inlet connection (pipe size)mm15151515
Heating flow and return connections (pipe size)mm22222222
Hot and cold water connections (pipe size)mm15151515
Heat exchanger materialStainless/AluminiumStainless SteelStainless SteelStainless SteelStainless Steel
Boiler lift weight (Dry boiler)kg38383839
NOx6666
NOx (En 15502-2-1)mg/kWh27333330
ErP efficiency%93939393
ErP decibel rating (sound power)dBa49494949
Maximum horizontal flue length 60/100m12121212
Maximum vertical flue length 60/100m16161616
Maximum horizontal flue length 80/125m39393939
Maximum vertical flue length 80/125m41414141

Vaillant range information · Detailed technical source

Discuss this range →
Vaillant ecoTEC plus Combi & System boiler

Combi / system

ecoTEC plus Combi & System

Also, we compare space and hot-water requirements for your Vaillant boiler installation. The remastered ecoTEC plus uses IoniDETECT combustion control and works with myVAILLANT connect. In addition, the range includes a storage-combi option for higher hot-water demand.

Domestic hot water flow rate (at Δ30˚C) **l/min · 12.4 · 15.2 · 17.0 · 19.0 · 21.0
ErP efficiency% · 93 · 94 · 94 · 94 · 94
Nominal heat output range at 50/30˚C (Condensing mode)kW · 2.8 – 21.2 · 3.9 – 26.5 · 4.2 – 32.2 · 5.0 – 32.3 · 5.0 – 32.3
Compare model specifications
Technical dataUnit of measureecoTEC plus 826 – 26kWecoTEC plus 832 – 32kWecoTEC plus 836 – 36kWecoTEC plus 840 – 40kWecoTEC plus 940 – 40kW
Boiler typeCombiCombiCombiCombiCombi
LPG compatibleYes – adaptiveYes – adaptiveYes – adaptiveNoNo
Article number00100360150010036016001003601700100360180010036114
PCDB numberTBCTBCTBCTBCTBC
Boiler dimensions (HxWxD)mm720 x 440 x 352720 x 440 x 352720 x 440 x 352720 x 440 x 386720 x 440 x 580
Side clearancemm55555
Top clearance (With 60/100 flue)mm165165165165165
Top clearance if using rear fluemmN/AN/AN/AN/AN/A
Bottom clearancemm180180180180180
Front clearance ~mm500500500500500
Nominal heat output range at 50/30°C (Condensing mode)kW2.8 – 21.23.9 – 26.54.2 – 32.25.0 – 32.35.0 – 32.3
Nominal heat output range at 80/60°C (Non condensing mode)kW2.5 – 19.83.5 – 24.93.7 – 29.94.5 – 29.84.5 – 29.8
Lowest water pressure to operate boilerbar0.70.70.70.70.7
Lowest water flow for operationl/min2.02.02.02.02.0
Domestic hot water flow rate (at Δ30˚C) **l/min12.415.217.019.021.0
Domestic hot water flow rate (at Δ35˚C) **l/min10.613.014.616.318.0
Hot water output temperature range˚C35-6535-6535-6535-6535-65
Gas inlet connection (pipe size)mm1515152222
Heating flow and return connections (pipe size)mm2222222222
Hot and cold water connections (pipe size)mm1515151515
Heat exchanger materialStainless/ AluminiumStainless SteelStainless SteelStainless SteelStainless SteelStainless Steel
Filling loop suppliedYES/NOYesYesYesYesYes
Boiler lift weight (Dry boiler)kg3637374160
Spacer frame availableYES/NOYesYesYesYesNo
NOx (En 15502-2-1)mg/kWh33.027.028.026.026.0
ErP efficiency%9394949494
ErP decibel rating (sound power)dB(A)4645474949
ErP efficiency Heating/DHWA+++ to DA/AA/AA/AA/AA/A
PCDB annual efficiency (SAP 2009/2012)%TBCTBCTBCTBCTBC
Maximum horizontal flue length 60/100m108888
Maximum vertical flue length 60/100m108888
Maximum horizontal flue length 80/125m2828282828
Maximum vertical flue length 80/125m3030303030
Rear flue optionsYES/NONoNoNoNoNo
Permissible flue classificationsC13, C33, C43, C53C13, C33, C43, C53C13, C33, C43, C53C13, C33, C43, C53C13, C33, C43, C53

Vaillant range information · Detailed technical source · Domestic range technical brochure

Discuss this range →
Vaillant ecoFIT pure Combi, System & Open Vent boiler

Combi / system / regular

ecoFIT pure Combi, System & Open Vent

Before your Vaillant boiler installation, we assess the existing system and recommend a suitable model. The ecoFIT pure family includes combi, system and open-vent formats. In addition, an aluminium heat exchanger and top or rear flue options give us flexibility when planning the installation.

Hot-water flow at 35°C rise (l/min)10.4 · 12.2 · 14.1
Hot-water output (kW)25.7 · 30.6 · 35.7
ErP efficiency (%)94 · 94 · 94
Compare model specifications
Combi model825830835
Hot-water output (kW)25.730.635.7
Hot-water flow at 35°C rise (l/min)10.412.214.1
Case H × W × D (mm)702 × 390 × 295702 × 390 × 295702 × 390 × 295
ErP efficiency (%)949494
Sound power dB(A)495152
Technical dataUnit of measureecoFIT pure 412ecoFIT pure 415ecoFIT pure 418ecoFIT pure 425ecoFIT pure 430ecoFIT pure 435
Boiler typeopen ventopen ventopen ventopen ventopen ventopen vent
Signature model output12kW15kW18kW25kW30kW35kW
Article number001002040000100204010010020402001002040300100204040010020405
Gas Council number41-694-0841-694-0941-694-1041-694-1141-694-1241-694-19
Boiler dimensions (HxWxD)mm600 x 375 x 295600 x 375 x 295600 x 375 x 295600 x 375 x 295600 x 375 x 295600 x 375 x 295
Nominal heat output range at 50/30˚C (Condensing mode)kW4.7 – 12.84.7 – 15.95.2 – 19.16.4 – 26.57.4 – 31.87 – 35.8
Nominal heat output range at 80/60˚C (Non condensing mode)kW4.5 – 12.34.5 – 15.25 – 18.36.1 – 25.47.1 – 30.57.2 – 34.8
Maximum flow temperature°C808080808080
Flow temperature range°C10 – 8010 – 8010 – 8010 – 8010 – 8010 – 80
Flow temperature factory setting°C757575757575
Approximate condensate volume at 50/30°Clitres/hr1.231.531.842.553.063.65
Modulation (max/min)1 : X1:3.31:41:51:4.91:4.91:4.9
Maximum heat output for water generationkW151825.2303535
Lowest water pressure to operate boilerbar0.30.30.30.30.30.3
Lowest water flow for operationl/min––––––
Lowest water pressure for maximum flow ratebar––––––
Domestic hot water flow rate (at DT = Δ35K) *l/min––––––
Hot water output temperature range˚C––––––
Expansion vessel sizelitres––––––
Gas inlet connection (pipe size)mm151515151515
Heating flow and return connections (pipe size)mm222222222222
Hot and cold water connections (pipe size)mm151515151515
Heat exchanger materialStainless/AluminiumAluminiumAluminiumAluminiumAluminiumAluminiumAluminium
Boiler lift weight (Dry boiler)kg222222222222
NOx class555555
NOx (En 15502-2-1)mg/kWh323339394032
ErP efficiency%949494949494
ErP decibel rating (sound power)dBa454851525555
Maximum horizontal flue length 60/100m101010101010
Maximum vertical flue length 60/100m101010101010
Maximum horizontal flue length 80/125m252525252525
Maximum vertical length 80/125m252525252525
Rear flue optionsYES/NOYesYesYesYesYesYes

Vaillant range information · Detailed technical source

Discuss this range →

Gas system boilers

ecoTEC exclusive boiler

System

ecoTEC exclusive

First, we check how this range would suit your Vaillant boiler installation. The current UK ecoTEC exclusive is a 27kW system boiler with Green iQ technology. Therefore, we compare it with your cylinder, heating demand and control preferences.

Domestic hot water flow rate (at DT = Δ35K) *l/min · –
ErP efficiency% · 94
Signature model output27kW
Compare model specifications
Technical dataUnit of measureecoTEC exclusive 627
Boiler typesystem
Signature model output27kW
Article number0010017063
Gas Council number41-694-02
Boiler dimensions (HxWxD)mm720 x 440 x 338
Nominal heat output range at 50/30˚C (Condensing mode)kW4.2 – 26.7
Nominal heat output range at 80/60˚C (Non condensing mode)kW3.7 – 24.7
Maximum flow temperature˚C80
Flow temperature range˚C30 – 80
Flow temperature factory setting˚C75
Approximate condensate volume at 50/30˚Clitres/hr2.52
Modulation (max/min)1 : X1:8.1
Maximum heat output for water generationkW30
Lowest water pressure to operate boilerbar–
Lowest water flow for operationl/min–
Lowest water pressure for maximum flow ratebar0.8
Domestic hot water flow rate (at DT = Δ35K) *l/min–
Hot water output temperature range˚C–
Expansion vessel sizelitres10
Gas inlet connection (pipe size)mm15
Heating flow and return connections (pipe size)mm22
Hot and cold water connections (pipe size)mm–
Heat exchanger materialStainless/AluminimumStainless Steel
Boiler lift weight (Dry boiler)kg37.5
NOx class5
NOx (En 15502-2-1)mg/kWh30
ErP efficiency%94
ErP decibel rating (sound power)dBa43
Maximum horizontal flue length 60/100m5.5
Maximum vertical flue length 60/100m8
Maximum horizontal flue length 80/125m32
Maximum vertical flue lengthm34

Vaillant range information · Detailed technical source

Discuss this range →

Gas regular boilers

ecoTEC plus Open Vent boiler

Regular

ecoTEC plus Open Vent

Also, we compare space and hot-water requirements for your Vaillant boiler installation. The ecoTEC plus open-vent family provides 12, 15, 18, 24, 30 and 35kW options. In addition, a rear flue option and compact footprint help when planning a traditional-system replacement.

Domestic hot water flow rate (at DT = Δ35K) *l/min · – · – · – · – · – · – · –
ErP efficiency% · 94 · 94 · 94 · 94 · 94 · 94 · 93
Signature model output12kW · 15kW · 18kW · 24kW · 24kW · 30kW · 35kW
Compare model specifications
Technical dataUnit of measureecoTEC plus 412ecoTEC plus 415ecoTEC plus 418ecoTEC plus 424ecoTEC plus 424 LPGecoTEC plus 430ecoTEC plus 435
Boiler typeopen ventopen ventopen ventopen ventopen ventopen ventopen vent
Signature model output12kW15kW18kW24kW24kW30kW35kW
Article number001002122000100212210010021222001002122300202313550010021224
Gas Council number41-694-1341-694-1441-694-1541-694-1641-694-1841-694-1741-044-76
Boiler dimensions (HxWxD)mm602 x 375 x 320602 x 375 x 320602 x 375 x 320602 x 375 x 320602 x 375 x 320602 x 375 x 320602 x 375 x 320
Nominal heat output range at 50/30˚C (Condensing mode)kW4.7 – 12.84.7 – 15.95.2 – 19.16.3 – 25.78 – 25.77.5 – 31.87.5 – 37.1
Nominal heat output range at 80/60˚C (Non condensing mode)kwW4.5 – 12.34.5 – 15.25 – 18.36.1 – 24.67.6 – 24.37.2 – 30.57.1 – 35.1
Maximum flow temperature˚C80808080808080
Flow temperature range˚C10 – 8010 – 8010 – 8010 – 8010 – 8010 – 8010 – 80
Flow temperature factory setting˚C75757575757575
Approximate condensate volume at 50/30˚Clitres/hr1.231.531.842.472.473.063.57
Modulation (max/min)1 : X1:41:41:51:4.91:3.91:4.91:4.9
Maximum heat output for water generationkW181825.230303535.1
Lowest water pressure to operate boilerbar–––––––
Lowest water flow for operationl/min–––––––
Lowest water pressure for maximum flow ratebar–––––––
Domestic hot water flow rate (at DT = Δ35K) *l/min–––––––
Hot water output temperature range˚C–––––––
NOx class6666666
NOx (En 15502-2-1)mg/kWh32333939354032
ErP efficiency%94949494949493
ErP decibel rating (sound power)dBa45485152495553
Maximum horizontal flue length 60/100m101010100.71010
Maximum vertial flue lengthm10101010–1010
Maximum horizontal flue length 80/125m25252525–2525
Maximum vertical flue length 80/125m25252525–2525
Gas inlet connection (pipe size)mm15
Heating flow and return connections (pipe size)mm22
Heat exchanger materialStainless/ AluminiumAluminium
Boiler lift weight (dry boiler)kg23.0
Maximum horizontal flue length 60/100m100.7*10
Rear flue optionsYes/NoYesNoYes
Permissible flue classificationsC13, C33, C43, C53 (LPG option is only suitable for C13 classification and can only be fitted with the top mounted horizontal flue supplied)

Vaillant range information · Detailed technical source

Discuss this range →

Compare figures carefully, because manufacturers publish different units and test conditions. For example, hot-water flow at a 35°C temperature rise differs from a figure measured at 40°C. In addition, ErP efficiency and seasonal efficiency to DIN use different test methods. Therefore, we explain the relevant figures before matching the exact model to your quotation.

What matters when choosing Vaillant boilers?

First, we calculate your home’s heating requirement, because radiator numbers alone cannot tell us the right boiler output. In addition, we compare the boiler’s minimum output so it can respond to smaller heating demands.

Next, we assess hot water, because the available water supply and temperature rise affect a combi’s flow at your taps. By contrast, a cylinder-based system needs the right storage capacity and recovery. Therefore, we discuss your showers, baths and daily routine together.

Also, we check the installation space, service access, flue route and controls. Although case dimensions are useful, the installation needs working room around the appliance too. As a result, your quotation covers a complete, practical boiler replacement.

Vaillant boiler installation planned around the home

Choose the right Vaillant boiler type

Vaillant combi boiler installation

Combi boilers

A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.

Discuss your boiler type →
Vaillant system boiler installation

System boilers

A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.

Discuss your boiler type →
Vaillant regular boiler installation

Regular boilers

A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.

Discuss your boiler type →

Natural gas and LPG boiler installations

For natural gas, we check the existing supply, boiler position and heating system. In addition, Vaillant offers LPG options within the appropriate ranges. We specify the correct model and fuel setup for your off-mains home.

For example, an LPG version or conversion applies to particular models rather than every boiler in a family. Therefore, our survey confirms the exact appliance and configuration before we quote. Our Gas Safe registered team completes the installation and commissioning.

Your Vaillant boiler installation, step by step

01

Survey your home

First, we discuss your rooms, heating and hot-water use. Also, we inspect the boiler, supply, radiators and controls, so your Vaillant boiler installation has a clear starting point.

02

Compare the options

Next, we explain suitable ranges, outputs and controls. Therefore, your quotation sets out the chosen boiler, fitting work and any system changes. You can then decide with a clear picture of the work.

03

Prepare and fit carefully

Then, we prepare the heating system and address cleaning and filtration. In addition, we fit the boiler, flue, pipework and controls with attention to service access and the finished appearance.

04

Commission and hand over

Finally, we test and commission the appliance, complete the records and explain the settings. Also, we show you the heating schedule and everyday controls, then help you arrange ongoing servicing.

INDEPENDENTLY REVIEWED

Heating work backed by hundreds of five-star reviews

For example, customers repeatedly mention punctual engineers, tidy workmanship and clear advice before, during and after their heating project.

★★★★★
The gas-boiler service was completed efficiently and the certificate arrived by email almost immediately.
F. Gillespie-WalkerGoogle Reviews — Google customer review
★★★★★
An older-property boiler upgrade finished on time, with tidy workmanship, punctual attendance and a flexible approach.
Which? Trusted TradersVerified heating customer, Oxfordshire
★★★★★
A last-minute boiler service was arranged quickly and completed efficiently by a team the customer readily recommends.
K. BrayWhich? Trusted Traders — Verified boiler-service customer

Review totals checked September 2026. Read the complete independent feedback on Google and Which? Trusted Traders.

Vaillant boiler questions

Can Oxyplumb install a Vaillant boiler?

We install Vaillant boilers across Oxfordshire, including straightforward replacements and wider heating upgrades. First, tell us about your current appliance so we can understand what you want to improve.

Which boiler output should I choose?

First, consider your home’s heating demand and hot-water use. Therefore, we assess the property, water supply and existing system before recommending an output. After all, the largest model is not automatically the right choice.

Can you replace a boiler from another brand?

Your existing boiler can be from another brand, because we plan the replacement around your heating system. First, we inspect the system, explain the options and quote for the work needed to fit your chosen Vaillant replacement.

Do you service and repair other boiler makes?

Our maintenance work also covers a broad range of boiler manufacturers, including older and less familiar makes. First, tell us your boiler’s make, model and fuel, so we can arrange the right engineer.

Local Vaillant boiler installation and ongoing care

For example, our team covers Faringdon, Wantage, Abingdon, Stanford in the Vale, Oxford, Bampton, Clanfield, Witney, Cumnor, Carterton, Uffington and Kingston Bagpuize. Choose your area to find its dedicated installation, servicing and repair pages.

Also, we maintain and repair boilers from a broad range of manufacturers. Explore our boiler servicing and boiler repair services, or compare our other manufacturer guides below.

Ready to choose your new Vaillant boiler?

First, tell Oxyplumb about your home and the work you have in mind. Then, we will help you choose the right boiler and provide a clear installation quotation.