Baxi boiler installation · Oxfordshire
Baxi boiler installation in Oxfordshire
Compare Baxi combi, system and heat-only boilers with Oxyplumb. We install new boilers, boiler replacements and upgrades, with advice on the right range, heating output and controls for your home.



Baxi boilers, chosen around your home
For Baxi boiler installation in Oxfordshire, our Gas Safe registered team starts with your property. First, we assess heating and hot-water demand. Then, we compare the 400, 600, 800 and wider Baxi-group catalogue, including appropriate LPG options.
Explore the Baxi boiler range
First, compare the Baxi boiler ranges below, using the images and key facts alongside each description. Then, open the model specifications to see the published figures, or ask our team to explain the choices for your home.
Gas combi and storage boilers

Combi
Baxi 800 Combi 2
First, we check how this range would suit your Baxi boiler installation. A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.
Compare model specifications
| Product Model | 824 Combi 2 | 830 Combi 2 | 836 Combi 2 |
|---|---|---|---|
| Product Code | 7814304 | 7814305 | 7814306 |
| Natural gas or LPG | Yes | Yes | Yes |
| Inlet supply pressure (natural gas) (mbar (nominal)) | 20 | 20 | 20 |
| Maximum Gas Rate (G20) Qmax (m3/hr) | 2.61 | 3.26 | 3.9 |
| kW (max) Gross (QnHs) | 20.6 | 25.7 | 25.7 |
| kW (min) Gross (QnHs) | 4.9 | 6 | 7.2 |
| kW (Max) (Pn) | 20 | 25 | 25 |
| kW (Min) (Pn) | 4.8 | 5.8 | 7.2 |
| kW (Max) (Pnc) | 21.8 | 27.1 | 27.1 |
| kW (Min) (Pnc) | 5.2 | 6.3 | 7.6 |
| Heat Input Domestic Hot Water (DHW) – kW max gross (QnwHs) | 27.4 | 30.9 | 36.9 |
| Heat Output Domestic Hot Water (DHW) – kW max | 24 | 30 | 36 |
| Water Heating Efficiency class | A | A | A |
| Permanent Live Required | Yes | Yes | Yes |
| External fuse rating (Amps) | 3 | 3 | 3 |
| Pump Overrun | Yes | Yes | Yes |
| Integral ‘boiler only’ Frost Thermostat | Yes | Yes | Yes |
| Maximum DHW flow rate (Delta T @ 35’C rise) (l/min) | 10.2 | 12.2 | 15 |
| Minimum DHW flow rate required (l/min) | 2 | 2 | 2 |
| Minimum Operating DHW pressure required (bar) | 0.5 | 0.5 | 0.5 |
| Integral Expansion Vessel -Size (litres) | 7 | 7 | 7 |
| Maximum Capacity of CH System (litres) | 100 | 100 | 100 |
| Integral Automatic Bypass | Yes | Yes | Yes |
| Installer Lift Weight (boiler) (kg) | 29.2 | 29.2 | 30.5 |

Combi
Baxi 400 Combi 2.1
Also, we compare space and hot-water requirements for your Baxi boiler installation. A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.
Compare model specifications
| Product Model | 424 Combi 2.1 | 430 Combi 2.1 | 436 Combi 2.1 |
|---|---|---|---|
| Product Code | 7872835 | 7872836 | 7872837 |
| Natural gas or LPG | Yes | Yes | Yes |
| Inlet supply pressure (natural gas) (mbar (nominal)) | 20 | 20 | 20 |
| Maximum Gas Rate (G20) Qmax (m³ / hr) | 2.61 | 3.26 | 3.9 |
| Heat Input CH (kW (max) Gross (QnHs)) | 20.6 | 25.7 | 25.7 |
| Heat Input CH (kW (min) Gross (QnHs)) | 4.9 | 6.0 | 7.2 |
| Heat Output CH (non-condensing) (kW (Max) (Pn)) | 20 | 25 | 25 |
| Heat Output CH (non-condensing) (kW (Min) (Pn)) | 4.8 | 5.8 | 7.2 |
| Heat Output CH (condensing) (kW (Max) (Pnc)) | 21.8 | 27.1 | 27.1 |
| Heat Output CH (condensing) (kW (Min) (Pnc)) | 5.2 | 6.3 | 7.6 |
| Heat Input domestic hot water (DHW) (kW max gross (QnwHs)) | 27.4 | 30.9 | 36.9 |
| Heat output domestic hot water (DHW) (kW max) | 24 | 30 | 36 |
| Water heating efficiency class | A | A | A |
| Permanent live required | Yes | Yes | Yes |
| External fuse rating (on connection board) (Amps) | F0.5A L250VP | F0.5A L250VP | F0.5A L250VP |
| Pump overrun | Yes | Yes | Yes |
| Integral ‘boiler only’ frost thermostat | Yes | Yes | Yes |
| Maximum DHW flow rate (Delta T @ 35’C rise) (l/min) | 10.2 | 12.2 | 15.0 |
| Minimum DHW flow rate required (l/min) | 2 | 2 | 2 |
| Minimum operating DHW pressure required (bar) | 0.5 | 0.5 | 0.5 |
| Integral expansion vessel (Size (litres)) | 7 | 7 | 7 |
| Maximum capacity of the CH system (Litres) | 100 | 100 | 100 |
| Integral automatic bypass | Yes | Yes | Yes |
| Installer Lift Weight (kg) | 28 | 29 | 30 |

Combi
Baxi 600 Combi 2 boilers
Before your Baxi boiler installation, we assess the existing system and recommend a suitable model. A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.
Compare model specifications
| Product Model | 624 Combi 2 | 630 Combi 2 | 636 Combi 2 |
|---|---|---|---|
| Product Code | 7796586 | 7796587 | 7796588 |
| Natural gas or LPG | Yes | Yes | Yes |
| Inlet supply pressure (natural gas) (mbar (nominal)) | 20 | 20 | 20 |
| Maximum Gas Rate (G20) Omax (m³ / hr) | 2.61 | 3.26 | 3.9 |
| kW (max) Gross (OnHs) | 20.6 | 25.7 | 25.7 |
| kW (min) Gross (OnHs) | 4.9 | 6 | 7.2 |
| kW (Max) (Pn) | 20 | 25 | 25 |
| kW (Min) (Pn) | 4.8 | 5.8 | 7.2 |
| kW (Max) (Pnc) | 21.8 | 27.1 | 27.1 |
| kW (Min) (Pnc) | 5.2 | 6.3 | 7.6 |
| Heat Input domestic hot water (DHW) (kW max gross (OnwHs)) | 27.4 | 30.9 | 36.9 |
| Heat Output domestic hot water (DHW) (kW max) | 24 | 30 | 36 |
| Water heating efficiency class | A | A | A |
| Permanent live required | Yes | Yes | Yes |
| External fuse rating (on connection board) (Amps) | F0.5A L250VP | F0.5A L250VP | F0.5A L250VP |
| Pump overrun | Yes | Yes | Yes |
| Integral ‘boiler only’ frost thermostat | Yes | Yes | Yes |
| Maximum DHW flow rate (Delta T @35’C rise) (l/min) | 10.2 | 12.2 | 15 |
| Minimum DHW flow rate required (l/min) | 2 | 2 | 2 |
| Minimum operating DHW pressure required (bar) | 0.5 | 0.5 | 0.5 |
| Integral expansion vessel – Size (litres) | 7 | 7 | 7 |
| Maximum capacity of the CH system (litres) | 100 | 100 | 100 |
| Integral automatic bypass | Yes | Yes | Yes |
| Installer Lift Weight (kg) | 28 | 29 | 30 |

Combi
Baxi Assure 500 Combi 2
First, we check how this range would suit your Baxi boiler installation. A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.
Compare model specifications
| Product Model | Baxi Assure 524 Combi 2 | Baxi Assure 530 Combi 2 | Baxi Assure 536 Combi 2 | |
|---|---|---|---|---|
| Product code | 7814309 | 7814310 | 7814311 | |
| Natural Gas or LPG | Yes | Yes | Yes | |
| Inlet supply pressure (NG) | 20 | 20 | 20 | |
| Maximum gas rate (G20) | 2.61 | 3.26 | 3.9 | |
| Heat Input CH | kW (min) gross (QnHs) | 20.6 | 25.7 | 25.7 |
| Heat Input CH | kW (min) gross (QnHs) | 4.9 | 6 | 7.2 |
| Heat output CH (non-condensing) | kW (max) (pn) | 20 | 25 | 25 |
| Heat output CH (condensing) | kW (max) (pn) | 4.8 | 5.8 | 7.2 |
| Heat input domestic hot water | kW (max)gross | 27.4 | 30.9 | 36.9 |
| Heat input domestic hot water | kW (max) | 24 | 30 | 36 |
| Water heating efficiency class | A | A | A | |
| Permanent live required | Yes | Yes | Yes | |
| Pumps overrun | Yes | Yes | Yes | |
| Maximum DHW flow rate (Delta T @ 35’C rise) | Vmin | 10.2 | 12.2 | 15 |
| Minimum DHW flow rate required | Vmin | 2 | 2 | 2 |
| Minimum operating DHW pressure required | bar | 0.5 | 0.5 | 0.5 |
| Integral expansion vessel | Size (litres) | 7 | 7 | 7 |
| Maximum capacity of the CH system | Litres | 100 | 100 | 100 |
| Integral automatic bypass | Yes | Yes | Yes |

Combi
Baxi MainEco Compact Combi
Also, we compare space and hot-water requirements for your Baxi boiler installation. A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.
Compare model specifications
| Main Eco Compact Combi | Units | Main Eco CompactCombi 25kW | Main Eco CompactCombi 30kW |
|---|---|---|---|
| Sales code (boiler only) | 7714519 | 7714161 | |
| Reset button | Yes | Yes | |
| User adjustable DHW temperature | Yes | Yes | |
| User adjustable CH temperature | Yes | Yes | |
| LED temp/status/fault diagnosis display | Yes | Yes | |
| Natural gas | Yes | Yes | |
| Nominal inlet supply pressure | mbar | 20 | 20 |
| Maximum gas rate | m3/h | 2.71 | 3.26 |
| Propane LPG | No | No | |
| Heat input central heating (CH) | kW Max Gross(QnHs) | 22.86 | 22.86 |
| kW Min Gross(QnHs) | 6.87 | 6.87 | |
| Heat output CH non-condensing | kW Max (Pn) | 20.00 | 20.00 |
| kW min (Pn) | 6.20 | 6.20 | |
| Heat output CH condensing | kW max (Pnc) | 21.16 | 21.20 |
| kW min (Pnc) | 6.70 | 6.70 | |
| Heat input domestic hot water | kW Max Gross (QnwHs) | 25.77 | 30.00 |
| Heat output domestic hot water | kW Max (Pn) | 25.00 | 30.93 |
| NOx | class | 6 | 6 |
| Space heating efficiency class | A | A | |
| Water heating declared load profile | XL | XL | |
| Water heating efficiency class | A | A | |
| Seasonal space heating energy efficiency | % | 93 | 93 |
| Electrical supply | Volts/Hz | 230/50 | 230/50 |
| Permanent live required | Yes | Yes | |
| Fitted electrical cable | No | No | |
| Power consumption | Watts | 68 | 68 |
| External fuse rating | Amps | 3 | 3 |
| Internal fuse rating | Amps | F2AH250V | F2AH250V |
| Ingress protection rating | IPX5D | IPX5D | |
| Integral ‘boiler only’ frost thermostat | Yes | Yes | |
| Multifit Pre-Plumb jig (7682545) | Yes | Yes | |
| Isolating valves | Yes | Yes | |
| Gas supply connection | mm | 22 | 22 |
| Central heating connections | mm | 22 | 22 |
| Domestic hot water connections | mm | 15 | 15 |
| Condensate drain connection | mm | 21.50 | 21.50 |
| Safety discharge connection | mm | 15 | 15 |
| Safety discharge pressure | bar | 3 | 3 |
| Temporary rigid filling loop included | Yes | Yes | |
| Domestic hot water output (raised 35°C) (max) | l/min | 10.2 | 12.2 |
| Domestic hot water operating flow rate (min) | l/min | 2* | 2* |
| Domestic hot water operating pressure (min) | bar | 0.5 | 0.5 |
| Domestic hot water system pressure (max) | bar | 8 | 8 |
| CH safety discharge pressure | bar | 3 | 3 |
| Integral automatic bypass | Yes | Yes | |
| Integral expansion vessel capacity | litres | 7 | 7 |
| Max capacity of central heating system | litres | 100 | 100 |
| Compartment ventilation requirement | No | No | |
| CH system inhibitor required | Yes | Yes | |
| 24 hour pump exercise | Yes | Yes | |
| Pump overrun | Yes | Yes | |
| Concentric flue diameters | mm | 60/100 | |
| Standard horizontal flue kit length (60/100mm) | mm | 685 | 685 |
| Max equiv length horizontal/vertical (60/100mm) | m | 10 | 10 |
| Equivalent length per 135º bend | m | 0.50 | 0.50 |
| Equivalent length per 93º bend | m | 1.00 | 1.00 |
| Max installation lift weight | kg | 29 | 29 |
| Gross packaged boiler weight | kg | 32 | 32 |

Combi
Baxi Duo-tec Compact Combi boilers
Before your Baxi boiler installation, we assess the existing system and recommend a suitable model. A compact cupboard-fit combi option with compatibility for Baxi uSense 2 controls. We explain the controls, water supply and installation layout during your survey.
Compare model specifications
| Case dimensions | Published value |
|---|---|
| Width (mm) | 395 |
| Height (mm) | 700 |
| Depth (mm) | 285 |

Combi
Baxi Platinum Compact Combi
First, we check how this range would suit your Baxi boiler installation. A compact cupboard-fit combi option with compatibility for Baxi uSense 2 controls. We explain the controls, water supply and installation layout during your survey.
Compare model specifications
| Case dimensions | Published value |
|---|---|
| Width (mm) | 395 |
| Height (mm) | 700 |
| Depth (mm) | 285 |
Gas regular boilers

Regular
Baxi 400 Heat
Also, we compare space and hot-water requirements for your Baxi boiler installation. A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.
Compare model specifications
| Product Model | 15kW | 18kW | 24kW | 30kW |
|---|---|---|---|---|
| Product Code | 7668933 | 7668934 | 7668935 | 7668936 |
| Operating mode selector switch with reset (Yes/No) | Yes | Yes | Yes | Yes |
| User adjustable CH temperature -Range – e.g. 30ºC to 80ºC (+/- 5ºC) | Yes | Yes | Yes | Yes |
| LED status/fault diagnosis display (Yes/nNo) | Yes | Yes | Yes | Yes |
| SAP 2009 Annual Efficiency (PCDB/SEDBUK) % | 89.2 | 89.2 | 89.1 | 89.1 |
| NOx class (1-5) | 5 | 5 | 5 | 6 |
| NOx (mg/kWh) | 20 | 21 | 23 | 21 |
| Sound Power Level, Indoors (LWA dB) | 33 | 34 | 35 | 49 |
| Space Heating Efficiency Class | A | A | A | A |
| Heat Input CH -kW max gross (QnHs) | 18.32 | 21.75 | 28.62 | 34.35 |
| Heat Input CH – kW min gross (QnHs) | 8.59 | 8.59 | 8.59 | 8.59 |
| Heat Output CH (non condensing) – kW max (Pn) | 16 | 19 | 25 | 30 |
| Heat Output CH (non condensing) – kW min (Pn) | 7.5 | 7.5 | 7.5 | 10.1 |
| Gas supply pipe size (mm) | 22 | 22 | 22 | 22 |
| Inlet supply pressure (natural gas) – mbar | 20 | 20 | 20 | 20 |
| Maximum gas rate (m3/hr) | 1.75 | 2.07 | 2.73 | 3.27 |
| Compartment ventilation required | No | No | No | No |
| Flow / return pipe size (mm) | 22 | 22 | 22 | 22 |
| Condensate discharge pipe (mm) | 21.5 | 21.5 | 21.5 | 21.5 |
| Electrical supply – Volts/Hz | 230V/50Hz | 230V/50Hz | 230V/ 50Hz | 230V/ 50Hz |
| Permanent live required (Yes/No) | No | No | No | No |
| Switched live (Yes/No) | Yes | Yes | Yes | Yes |
| Electrical power cable fitted as standard (1m of 3 core) | Yes | Yes | Yes | Yes |
| Power consumption (Watts) | 20 | 23 | 33 | 44 |
| External fuse rating (Amps)3 | 3 | 3 | 3 | |
| Internal fuse rating | 1.6T | 1.6T | 1.6T | 1.6T |
| Boiler IP rating (electrical protection) -Approval category | IPX4D | IPX4D | IPX4D | IPX4D |
| Pump overrun (Yes/No) | No | No | No | No |
| Standard telescopic concentric flue (Length in mm) | 315-500 | 315-500 | 315-500 | 315-500 |
| Standard in-case rear telescopic concentric flue (Length in mm) | 220-345 | 220-345 | 220-345 | 220-345 |
| Horizontal concentric (60/100mm) – Max equivalent length (m) | 6 | 6 | 6 | 6 |
| Horizontal concentric (60/100mm) – Reduction per 135º bend (m) | 0.5 | 0.5 | 0.5 | 0.5 |
| Horizontal concentric (60/100mm) – Reduction per 93º bend (m) | 1 | 1 | 1 | 1 |
| Installer lift weight -Max (kg) | 17.4 | 17.4 | 17.4 | 19.5 |
| Gross packaged boiler weight (kg) | 21.5 | 21.5 | 21.5 | 21.5 |

Regular
Baxi 800 Heat boilers
Before your Baxi boiler installation, we assess the existing system and recommend a suitable model. A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.
Compare model specifications
| Product Model | 16 | 19 | 25 | 30 |
|---|---|---|---|---|
| Product Code | 7749866 | 7898832 | 7749868 | 7749869 |
| Operating mode selector switch with reset (Yes/No) | Yes | Yes | Yes | Yes |
| User adjustable CH temperature (Range – e.g. 45° to 82°) | Yes | Yes | Yes | Yes |
| LED temp/status/fault diagnosis display (Yes/No) | Yes | Yes | Yes | Yes |
| Baxi twin channel wired programmer -7212443 | Optional | Optional | Optional | Optional |
| Baxi room thermostat -720971601 | Optional | Optional | Optional | Optional |
| Boiler Plus ErP (%) | 93 | 93 | 93 | |
| SAP 2009 annual efficiency (PCDB/SEDBUK) % | 89.2 | 89.2 | 89.1 | 89.1 |
| NOx class | 6 | 6 | 6 | 6 |
| NOx (mg/kWh) | 20 | 25 | 24 | 24 |
| Sound Power Level, Indoors (LWA dB) | 39 | 41 | 45 | 49 |
| Space Heating Efficiency Class | A | A | A | A |
| Heat Input CH – kW max gross (QnHs) | 18.32 | 21.75 | 28.62 | 34.35 |
| Heat Input CH – kW min gross (QnHs) | 8.59 | 8.59 | 8.59 | 8.59 |
| Heat Output CH (non condensing) kW (Pn) | 16 | 19 | 25 | 30 |
| Heat Output CH (non condensing) kW (Pn) | 7.5 | 6.4 | 7.5 | 7.5 |
| Gas supply connection (mm) | 22 | 22 | 22 | 22 |
| Inlet supply pressure (natural gas) mbar | 20 | 20 | 20 | 20 |
| Maximum gas rate (m3/hr) | 1.75 | 2.07 | 2.73 | 3.27 |
| Compartment ventilation required (Yes/No) | No | No | No | No |
| Flow / return pipe size (mm) | 22 | 22 | 22 | 22 |
| Condensate discharge pipe size (mm) | 21.5 | 21.5 | 21.5 | 21.5 |
| Electrical supply (Volts/Hz) | 230V/50Hz | 230V/ 50Hz | 230V/50Hz | 230V/50Hz |
| Permanent live required (Yes/No) | No | No | No | No |
| Switched live (Yes/No) | Yes | Yes | Yes | Yes |
| Electrical power cable fitted as standard (1m of 3 core) | Yes | Yes | Yes | Yes |
| Power consumption (Watts) | 20 | 23 | 33 | 44 |
| External fuse rating (Amps) | 3 | 3 | 3 | 3 |
| Internal fuse rating | 1.6T | 1.6T | 1.6T | 1.6T |
| Boiler IP rating (electrical protection) -Approval category | IPX4D | IPX4D | IPX4D | IPX4D |
| Pump overrun (Yes/No) | No | No | No | No |
| Standard telescopic concentric flue (Length in mm) | 315-500 | 315-500 | 315-500 | 315-500 |
| Horizontal and Vertical concentric (60/100 mm) – Max equivalent length (m) | 6 | 6 | 6 | 6 |
| Horizontal and Vertical concentric (60/100 mm) – Reduction per 135° bend (m) | 0.5 | 0.5 | 0.5 | 0.5 |
| Horizontal and Vertical concentric (60/100 mm) – Reduction per 93° bend (m) | 1 | 1 | 1 | 1 |
| Installer lift weight (boiler) Max (kg) | 17.4 | 17.4 | 17.4 | 19.5 |
| Gross packaged boiler weight (kg) | 21.3 | 19.4 | 21.3 | 21.3 |

Regular
Baxi 600 Heat
First, we check how this range would suit your Baxi boiler installation. A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.
Compare model specifications
| Product Model | 16 Heat | 19 Heat | 25 Heat |
|---|---|---|---|
| Product Code | 7711999 | 7712020 | 7712022 |
| Operating mode selector switch with reset (Yes/No) | Yes | Yes | Yes |
| User adjustable CH temperature (Range – e.g. 45° to 82°) | Yes | Yes | Yes |
| LED temp/status/fault diagnosis display (Yes/No) | Yes | Yes | Yes |
| Baxi twin channel wired programmer – 7212443 | Optional | Optional | Optional |
| Baxi room thermostat – 720971601 | Optional | Optional | Optional |
| Boiler Plus ErP (%) | 93 | 93 | 93 |
| SAP 2009 annual efficiency (PCDB/SEDBUK) % | 89.2 | 89.2 | 89.1 |
| NOx class | 6 | 6 | 6 |
| NOx (mg/kWh) | 20 | 21 | 24 |
| Sound Power Level, Indoors (LWA dB) | 39 | 41 | 45 |
| Space Heating Efficiency Class | A | A | A |
| Heat Input CH – kW max gross (QnHs) | 18.32 | 21.75 | 28.62 |
| Heat Input CH – kW min gross (QnHs) | 8.59 | 8.59 | 8.59 |
| Heat Output CH (non condensing) – kW (Pn) | 16 | 19 | 25 |
| Heat Output CH (non condensing) – kW (Pn) | 7.5 | 7.5 | 7.5 |
| Gas supply connection (mm) | 22 | 22 | 22 |
| Inlet supply pressure (natural gas) – mbar | 20 | 20 | 20 |
| Maximum gas rate (m3/hr) | 1.75 | 2.07 | 2.73 |
| Compartment ventilation required (Yes/No) | No | No | No |
| Flow / return pipe size (mm) | 22 | 22 | 22 |
| Condensate discharge pipe size (mm) | 21.5 | 21.5 | 21.5 |
| Electrical supply – Volts/Hz | 230V/50Hz | 230V/50Hz | 230V/50Hz |
| Permanent live required (Yes/No) | No | No | No |
| Switched live (Yes/No) | Yes | Yes | Yes |
| Electrical power cable fitted as standard (1m of 3 core) | Yes | Yes | Yes |
| Power consumption (Watts) | 20 | 23 | 33 |
| External fuse rating (Amps) | 3 | 3 | 3 |
| Internal fuse rating | 1.6T | 1.6T | 1.6T |
| Boiler IP rating (electrical protection) – Approval category | IPX4D | IPX4D | IPX4D |
| Pump overrun (Yes/No) | No | No | No |
| Standard telescopic concentric flue (Length in mm) | 315-500 | 315-500 | 315-500 |
| Horizontal and Vertical concentric (60/100 mm) – Max equivalent length (m) | 6 | 6 | 6 |
| Horizontal and Vertical concentric (60/100 mm) – Reduction per 135° bend (m) | 0.5 | 0.5 | 0.5 |
| Horizontal and Vertical concentric (60/100 mm) – Reduction per 93° bend (m) | 1 | 1 | 1 |
| Installer lift weight (boiler) – Max (kg) | 17.4 | 17.4 | 17.4 |
| Gross packaged boiler weight (kg) | 19.5 | 19.5 | 19.5 |

Regular
Baxi Assure Heat
Also, we compare space and hot-water requirements for your Baxi boiler installation. A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.
Compare model specifications
| Product Model | Baxi Assure 16 Heat | Baxi Assure 19 Heat | Baxi Assure 25 Heat | |
|---|---|---|---|---|
| Product code | 7749447 | 7749448 | 7749449 | |
| Natural Gas | Yes | Yes | Yes | |
| Propane LPG | N/A | N/A | N/A | |
| Inlet supply pressure | 20 | 20 | 20 | |
| Maximum gas rate (G20) | 1.75 | 2.07 | 2.73 | |
| Heat Input CH | kW (min) gross (QnHs) | 18.32 | 21.75 | 28.62 |
| Heat Input CH | kW (min) gross (QnHs) | 8.59 | 8.59 | 8.59 |
| Heat output CH (non-condensing) | kW (max) (pn) | 16 | 19 | 25 |
| Heat output CH (non-condensing) | kW (max) (pn) | 7.5 | 7.5 | 7.5 |
| Permanent live required | No | No | No | |
| External fuse rating | 3 | 3 | 3 | |
| Pumps overrun | No | No | No |

Regular
Baxi MainEco Compact Heat boilers
Before your Baxi boiler installation, we assess the existing system and recommend a suitable model. A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.
Compare model specifications
| Main Eco Compact Heat | Units | Main Eco CompactHeat 15kW | Main Eco CompactHeat 18kW | Main Eco CompactHeat 24kW | Main Eco CompactHeat 30kW |
|---|---|---|---|---|---|
| Sales code (boiler only)Controls and accessories | 7712025 | 7712026 | 7712028 | 7712029 | |
| Operating mode selector switch with reset | Yes | Yes | Yes | Yes | |
| User adjustable CH temperature | Range 30°C to 80°C | Yes | Yes | Yes | Yes |
| LED temp/status/ fault diagnosis display | Yes | Yes | Yes | Yes | |
| NOx class | 6 | 6 | 6 | 6 | |
| NOx | mg/kWh | 20 | 21 | 24 | 24 |
| Sound power level, indoors | LWA dB | 33 | 34 | 37 | 37 |
| Space heating efficiency class | A | A | A | A | |
| Heat input central heating (CH) | kW max gross (QnHs) – kW min gross (QnHs) | 18.32 – 8.59 | 21.75 – 8.59 | 28.62 – 8.59 | 34.35 – 8.59 |
| Heat output CH (non-condensing) | kW max (Pn) – kW min (Pn) | 16 – 7.5 | 19 – 7.5 | 25 – 7.5 | 30 – 7.5 |
| Gas supply pipe size | mm | 22 | 22 | 22 | 22 |
| Inlet supply pressure (natural gas) | mbar | 20 | 20 | 20 | 20 |
| Maximum gas rate | m3/hr | 1.75 | 2.07 | 2.73 | 3.27 |
| Compartment ventilation required | No | No | No | No | |
| Flow/return pipe | mm | 22 | 22 | 22 | 22 |
| Condensate discharge pipe connection | mm | 21.5 | 21.5 | 21.5 | 21.5 |
| Electrical supply | Volts / Hz | 230V / 50Hz | 230V / 50Hz | 230V / 50Hz | 230V / 50Hz |
| Permanent live required | No | No | No | No | |
| Power consumption | Watts | 20 | 23 | 33 | 44 |
| External fuse rating | Amps | 3 | 3 | 3 | 3 |
| Internal fuse rating | 1.6T | 1.6T | 1.6T | 1.6T | |
| Boiler IP rating (electrical protection) | Approval Category | IPX4D | IPX4D | IPX4D | IPX4D |
| Pump overrun | No | No | No | No | |
| Standard telescopic concentric flue | mm | 315-500 | 315-500 | 315-500 | 315-500 |
| Max equivalent length (m) | 6 | 6 | 6 | 6 | |
| Reduction Per 135º bend (m) | 0.5 | 0.5 | 0.5 | 0.5 | |
| Reduction Per 93º bend (m) | 1 | 1 | 1 | 1 | |
| Gross packaged boiler weight | (Max)kg | 19.5 | 19.5 | 19.5 | 21.5 |
| Maximum installation lift weight | kg | 17.4 | 17.4 | 17.4 | 19.5 |

Regular
Potterton Titanium Heat
First, we check how this range would suit your Baxi boiler installation. A Baxi-group heat-only option for cylinder-based heating. We inspect the pump, valves and existing arrangement before specifying the replacement.
Compare model specifications
| Case dimensions | Published value |
|---|---|
| Width (mm) | 370 |
| Height (mm) | 625 |
| Depth (mm) | 270 |
Gas system boilers

System
Baxi 800 System 2
Also, we compare space and hot-water requirements for your Baxi boiler installation. A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.
Compare model specifications
| Product model | 18 System | 24 System | 30 System |
|---|---|---|---|
| Product code | 7814313 | 7814314 | 7814315 |
| Natural Gas or LPG | Yes | Yes | Yes |
| Inlet supply pressure (natural gas) mbar(nominal) | 20 | 20 | 20 |
| Maximum gas rate (G20) Qmax (m3/hr) | 1.97 | 2.61 | 3.26 |
| Heat input CHkW (max) gross (QnHs) | 18.6 | 24.7 | 30.9 |
| Heat input CHkW (min) gross (QnHs) | 4.9 | 4.9 | 6 |
| Heat output CH (non-condensing) – kW (max) (Pn) | 18 | 24 | 30 |
| Heat output CH (non-condensing) – kW (min) (Pn) | 4.8 | 4.8 | 5.8 |
| Heat output CH (condensing) – kW (max) (Pnc) | 19.9 | 26.3 | 32.4 |
| Heat output CH (condensing) – kW (min) (Pnc) | 5.2 | 5.2 | 6.4 |
| Heat input domestic hot water (DHW) – kW (max) gross (QnwHs) | n/a | n/a | n/a |
| Heat input domestic hot water (DHW) – kW (max) | n/a | n/a | n/a |
| Water heating efficiency class | A | A | A |
| Permanent live required | Yes | Yes | Yes |
| Pump overrun | Yes | Yes | Yes |
| Integral ‘boiler only’ frost thermostat | Yes | Yes | Yes |
| Maximum DHW flow rate (Delta T @ 35c rise) (I/min) | n/a | n/a | n/a |
| Minimum DHW flow rate required (I/min) | 2 | 2 | 2 |
| Minimum operating DHW pressure required (bar) | 0.5 | 0.5 | 0.5 |
| Integral expansion vessel (litres) | 7 | 7 | 7 |
| Maximum capacity of CH system (litres) | 100 | 100 | 100 |
| Installer lift weight (boiler) (kg) | 29 | 30 | 30 |

System
Baxi 600 System 2 boilers
Before your Baxi boiler installation, we assess the existing system and recommend a suitable model. A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.
Compare model specifications
| Product model | 15 System | 18 System | 24 System |
|---|---|---|---|
| Product code | 7798687 | 7802020 | 7802241 |
| Natural Gas or LPG | Yes | Yes | Yes |
| Inlet supply pressure (natural gas) mbar(nominal) | 20 | 20 | 20 |
| Maximum gas rate (G20) Qmax (m3/hr) | 1.64 | 1.97 | 2.61 |
| Heat input CHkW (max) gross (QnHs) | 15.5 | 18.6 | 24.7 |
| Heat input CHkW (min) gross (QnHs) | 4.9 | 4.9 | 4.9 |
| Heat output CH (non-condensing) – kW (max) (Pn) | 15 | 18 | 24 |
| Heat output CH (non-condensing) – kW (min) (Pn) | 4.8 | 4.8 | 4.8 |
| Heat output CH (condensing) – kW (max) (Pnc) | 16.3 | 19.9 | 26.3 |
| Heat output CH (condensing) – kW (min) (Pnc) | 5.2 | 5.2 | 5.2 |
| Heat input domestic hot water (DHW) – kW (max) gross (QnwHs) | n/a | n/a | n/a |
| Heat input domestic hot water (DHW) – kW (max) | n/a | n/a | n/a |
| Water heating efficiency class | A | A | A |
| Permanent live required | Yes | Yes | Yes |
| Pump overrun | Yes | Yes | Yes |
| Integral ‘boiler only’ frost thermostat | Yes | Yes | Yes |
| Maximum DHW flow rate (Delta T @ 35c rise) (I/min) | n/a | n/a | n/a |
| Minimum DHW flow rate required (I/min) | 2 | 2 | 2 |
| Minimum operating DHW pressure required (bar) | 0.5 | 0.5 | 0.5 |
| Integral expansion vessel (litres) | 7 | 7 | 7 |
| Maximum capacity of CH system (litres) | 100 | 100 | 100 |
| Installer lift weight (boiler) (kg) | 28 | 29 | 30 |

System
Baxi MainEco Compact System
First, we check how this range would suit your Baxi boiler installation. A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.
Compare model specifications
| Main Eco Compact System | Units | Main Eco Compact System 15kW | Main Eco Compact System 18kW |
|---|---|---|---|
| Sales code (boiler only) | 7714605 | 7714606 | |
| Reset switch | Yes | Yes | |
| User adjustable CH temperature | Yes | Yes | |
| LED operating status display | Yes | Yes | |
| Natural Gas | Yes | Yes | |
| Nominal inlet supply pressure | mbar | 20 | 20 |
| Maximum gas rate | m3/hr | 1.64 | 1.96 |
| Heat input central heating (CH) | kW max gross (QnHs) | 17.16 | 20.60 |
| kW min gross (QnHs) | 5.15 | 5.15 | |
| Heat output CH non-condensing | kW max (Pn) | 15.00 | 18.00 |
| kW min (Pn) | 4.50 | 4.50 | |
| Heat output CH condensing | kW max (Pnc) | 16.2 | 19.4 |
| kW min (Pnc) | 4.9 | 4.9 | |
| NOx | class | 6 | 6 |
| Sound power level, indoors | LWA dB | 49 | 51 |
| Seasonal space heating energy efficiency | % | 93 | 93 |
| Electrical supply | Volts/Hz | 230/50 | 230/50 |
| Permanent live required | Yes | Yes | |
| Switched live | Yes | Yes | |
| Power consumption | Watts | 46 | 56 |
| External fuse rating | Amps | 3 | 3 |
| Internal fuse rating | F2HA250V | F2HA250V | |
| Boiler IP rating (electrical protection) | Approval category | IPX5D | IPX5D |
| Integral ‘boiler only’ frost thermostat | Yes | Yes | |
| Pump overrun | Yes | Yes | |
| Multifit Pre-Plumb jig (7682545) | Yes | Yes | |
| Isolating valves | Yes | Yes | |
| Gas supply connection | mm | 22 | 22 |
| Central heating connections | mm | 22 | 22 |
| Condensate drain connection | mm | 21.5 | 21.5 |
| Safety discharge connection | mm | 15 | 15 |
| Safety discharge pressure | bar | 3 | 3 |
| Integral automatic bypass | Yes | Yes | |
| Integral expansion vessel | litres | 7 | 7 |
| Maximum capacity of CH system | litres | 100 | 100 |
| 24hr pump exercise | Yes | Yes | |
| Pump overrun | Yes | Yes | |
| Concentric flue diameter | mm | 60/100 | 60/100 |
| Standard horizontal flue kit length (ø 60/100) | mm | 685 | 685 |
| Maximum equivalent vertical length (ø 60/100) | m | 10 | 10 |
| Equivalent length per 135° bend | m | 0.50 | 0.50 |
| Equivalent length per 93° bend | m | 1 | 1 |
| Gross packaged boiler weight | kg | 31.2 | 31.2 |
| Maximum installation lift weight | kg | 28.06 | 28.06 |

System
Baxi Assure 500 System 2
Also, we compare space and hot-water requirements for your Baxi boiler installation. A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.
Compare model specifications
| Product Model | Baxi Assure 515 System 2 | Baxi Assure 518 System 2 | Baxi Assure 524 System 2 | |
|---|---|---|---|---|
| Product code | 7814318 | 7814319 | 7814320 | |
| Natural Gas or LPG | Yes | Yes | Yes | |
| Inlet supply pressure (NG) | 20 | 20 | 20 | |
| Maximum gas rate (G20) | 1.64 | 1.97 | 2.61 | |
| Heat Input CH | kW (max) gross (QnHs) | 15.5 | 18.6 | 24.7 |
| Heat Input CH | kW (min) gross (QnHs) | 4.9 | 4.9 | 4.9 |
| Heat output CH (non-condensing) | kW (max) (pn) | 15 | 18 | 24 |
| Heat output CH (non-condensing) | kW (min) (pn) | 4.8 | 4.8 | 4.8 |
| Heat output CH (condensing) | 16.3 | 19.9 | 26.3 | |
| Heat output CH (condensing) | 5.2 | 5.2 | 5.2 | |
| Heat input domestic hot water | N/A | N/A | N/A | |
| Heat input domestic hot water | N/A | N/A | N/A | |
| Water heating efficiency class | A | A | A | |
| Permanent live required | Yes | Yes | Yes | |
| Pumps overrun | Yes | Yes | Yes | |
| Integral ‘boiler only’ frost thermostat | Yes | Yes | Yes | |
| Maximum DHW flow rate (Delta T @ 35’C rise) | Vmin | N/A | N/A | N/A |
| Minimum DHW flow rate required | Vmin | 2 | 2 | 2 |
| Minimum operating DHW pressure required | bar | 0.5 | 0.5 | 0.5 |
| Integral expansion vessel | Size (litres) | 7 | 7 | 7 |
| Maximum capacity of the CH system | Litres | 100 | 100 | 100 |
| Integral automatic bypass | Yes | Yes | Yes |

System
Baxi Megaflo Compact System boilers
Before your Baxi boiler installation, we assess the existing system and recommend a suitable model. A compact system-boiler option for a home with a separate hot-water cylinder. We assess the cylinder, heating load and controls together.
Compare model specifications
| Case dimensions | Published value |
|---|---|
| Width (mm) | 395 |
| Height (mm) | 700 |
| Depth (mm) | 285 |
Compare figures carefully, because manufacturers publish different units and test conditions. For example, hot-water flow at a 35°C temperature rise differs from a figure measured at 40°C. In addition, ErP efficiency and seasonal efficiency to DIN use different test methods. Therefore, we explain the relevant figures before matching the exact model to your quotation.
What matters when choosing Baxi boilers?
First, we calculate your home’s heating requirement, because radiator numbers alone cannot tell us the right boiler output. In addition, we compare the boiler’s minimum output so it can respond to smaller heating demands.
Next, we assess hot water, because the available water supply and temperature rise affect a combi’s flow at your taps. By contrast, a cylinder-based system needs the right storage capacity and recovery. Therefore, we discuss your showers, baths and daily routine together.
Also, we check the installation space, service access, flue route and controls. Although case dimensions are useful, the installation needs working room around the appliance too. As a result, your quotation covers a complete, practical boiler replacement.

Choose the right Baxi boiler type

Combi boilers
A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.
Discuss your boiler type →
System boilers
A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.
Discuss your boiler type →
Regular boilers
A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.
Discuss your boiler type →Natural gas and LPG boiler installations
For natural gas, we check the existing supply, boiler position and heating system. In addition, Baxi offers LPG options within the appropriate ranges. We specify the correct model and fuel setup for your off-mains home.
For example, an LPG version or conversion applies to particular models rather than every boiler in a family. Therefore, our survey confirms the exact appliance and configuration before we quote. Our Gas Safe registered team completes the installation and commissioning.
Your Baxi boiler installation, step by step
Survey your home
First, we discuss your rooms, heating and hot-water use. Also, we inspect the boiler, supply, radiators and controls, so your Baxi boiler installation has a clear starting point.
Compare the options
Next, we explain suitable ranges, outputs and controls. Therefore, your quotation sets out the chosen boiler, fitting work and any system changes. You can then decide with a clear picture of the work.
Prepare and fit carefully
Then, we prepare the heating system and address cleaning and filtration. In addition, we fit the boiler, flue, pipework and controls with attention to service access and the finished appearance.
Commission and hand over
Finally, we test and commission the appliance, complete the records and explain the settings. Also, we show you the heating schedule and everyday controls, then help you arrange ongoing servicing.
INDEPENDENTLY REVIEWED
Heating work backed by hundreds of five-star reviews
For example, customers repeatedly mention punctual engineers, tidy workmanship and clear advice before, during and after their heating project.
The gas-boiler service was completed efficiently and the certificate arrived by email almost immediately.
An older-property boiler upgrade finished on time, with tidy workmanship, punctual attendance and a flexible approach.
A last-minute boiler service was arranged quickly and completed efficiently by a team the customer readily recommends.
Review totals checked September 2026. Read the complete independent feedback on Google and Which? Trusted Traders.
Baxi boiler questions
Can Oxyplumb install a Baxi boiler?
We install Baxi boilers across Oxfordshire, including straightforward replacements and wider heating upgrades. First, tell us about your current appliance so we can understand what you want to improve.
Which boiler output should I choose?
First, consider your home’s heating demand and hot-water use. Therefore, we assess the property, water supply and existing system before recommending an output. After all, the largest model is not automatically the right choice.
Can you replace a boiler from another brand?
Your existing boiler can be from another brand, because we plan the replacement around your heating system. First, we inspect the system, explain the options and quote for the work needed to fit your chosen Baxi replacement.
Do you service and repair other boiler makes?
Our maintenance work also covers a broad range of boiler manufacturers, including older and less familiar makes. First, tell us your boiler’s make, model and fuel, so we can arrange the right engineer.
Local Baxi boiler installation and ongoing care
For example, our team covers Faringdon, Wantage, Abingdon, Stanford in the Vale, Oxford, Bampton, Clanfield, Witney, Cumnor, Carterton, Uffington and Kingston Bagpuize. Choose your area to find its dedicated installation, servicing and repair pages.
Also, we maintain and repair boilers from a broad range of manufacturers. Explore our boiler servicing and boiler repair services, or compare our other manufacturer guides below.
Ready to choose your new Baxi boiler?
First, tell Oxyplumb about your home and the work you have in mind. Then, we will help you choose the right boiler and provide a clear installation quotation.





OFTEC and Gas Safe registered.


















Worcester Bosch
Vaillant
Grant oil boilers