Baxi boiler installation · Oxfordshire

Baxi boiler installation in Oxfordshire

Compare Baxi combi, system and heat-only boilers with Oxyplumb. We install new boilers, boiler replacements and upgrades, with advice on the right range, heating output and controls for your home.

BaxiGas Safe registered — registration 622923Which? Trusted Trader
Baxi boilers for a new boiler installation

Baxi boilers, chosen around your home

For Baxi boiler installation in Oxfordshire, our Gas Safe registered team starts with your property. First, we assess heating and hot-water demand. Then, we compare the 400, 600, 800 and wider Baxi-group catalogue, including appropriate LPG options.

Explore the Baxi boiler range

First, compare the Baxi boiler ranges below, using the images and key facts alongside each description. Then, open the model specifications to see the published figures, or ask our team to explain the choices for your home.

Gas combi and storage boilers

Baxi 800 Combi 2 boiler

Combi

Baxi 800 Combi 2

First, we check how this range would suit your Baxi boiler installation. A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.

Maximum DHW flow rate (Delta T @ 35’C rise) (l/min)10.2 · 12.2 · 15
Heat Output Domestic Hot Water (DHW) – kW max24 · 30 · 36
Water Heating Efficiency classA · A · A
Compare model specifications
Product Model824 Combi 2830 Combi 2836 Combi 2
Product Code781430478143057814306
Natural gas or LPGYesYesYes
Inlet supply pressure (natural gas) (mbar (nominal))202020
Maximum Gas Rate (G20) Qmax (m3/hr)2.613.263.9
kW (max) Gross (QnHs)20.625.725.7
kW (min) Gross (QnHs)4.967.2
kW (Max) (Pn)202525
kW (Min) (Pn)4.85.87.2
kW (Max) (Pnc)21.827.127.1
kW (Min) (Pnc)5.26.37.6
Heat Input Domestic Hot Water (DHW) – kW max gross (QnwHs)27.430.936.9
Heat Output Domestic Hot Water (DHW) – kW max243036
Water Heating Efficiency classAAA
Permanent Live RequiredYesYesYes
External fuse rating (Amps)333
Pump OverrunYesYesYes
Integral ‘boiler only’ Frost ThermostatYesYesYes
Maximum DHW flow rate (Delta T @ 35’C rise) (l/min)10.212.215
Minimum DHW flow rate required (l/min)222
Minimum Operating DHW pressure required (bar)0.50.50.5
Integral Expansion Vessel -Size (litres)777
Maximum Capacity of CH System (litres)100100100
Integral Automatic BypassYesYesYes
Installer Lift Weight (boiler) (kg)29.229.230.5

Baxi range information

Discuss this range →
400 Combi 2.1 boiler

Combi

Baxi 400 Combi 2.1

Also, we compare space and hot-water requirements for your Baxi boiler installation. A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.

Maximum DHW flow rate (Delta T @ 35’C rise) (l/min)10.2 · 12.2 · 15.0
Heat output domestic hot water (DHW) (kW max)24 · 30 · 36
Water heating efficiency classA · A · A
Compare model specifications
Product Model424 Combi 2.1430 Combi 2.1436 Combi 2.1
Product Code787283578728367872837
Natural gas or LPGYesYesYes
Inlet supply pressure (natural gas) (mbar (nominal))202020
Maximum Gas Rate (G20) Qmax (m³ / hr)2.613.263.9
Heat Input CH (kW (max) Gross (QnHs))20.625.725.7
Heat Input CH (kW (min) Gross (QnHs))4.96.07.2
Heat Output CH (non-condensing) (kW (Max) (Pn))202525
Heat Output CH (non-condensing) (kW (Min) (Pn))4.85.87.2
Heat Output CH (condensing) (kW (Max) (Pnc))21.827.127.1
Heat Output CH (condensing) (kW (Min) (Pnc))5.26.37.6
Heat Input domestic hot water (DHW) (kW max gross (QnwHs))27.430.936.9
Heat output domestic hot water (DHW) (kW max)243036
Water heating efficiency classAAA
Permanent live requiredYesYesYes
External fuse rating (on connection board) (Amps)F0.5A L250VPF0.5A L250VPF0.5A L250VP
Pump overrunYesYesYes
Integral ‘boiler only’ frost thermostatYesYesYes
Maximum DHW flow rate (Delta T @ 35’C rise) (l/min)10.212.215.0
Minimum DHW flow rate required (l/min)222
Minimum operating DHW pressure required (bar)0.50.50.5
Integral expansion vessel (Size (litres))777
Maximum capacity of the CH system (Litres)100100100
Integral automatic bypassYesYesYes
Installer Lift Weight (kg)282930

Baxi range information

Discuss this range →
Baxi 600 Combi 2 boiler

Combi

Baxi 600 Combi 2 boilers

Before your Baxi boiler installation, we assess the existing system and recommend a suitable model. A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.

Maximum DHW flow rate (Delta T @35’C rise) (l/min)10.2 · 12.2 · 15
Heat Output domestic hot water (DHW) (kW max)24 · 30 · 36
Water heating efficiency classA · A · A
Compare model specifications
Product Model624 Combi 2630 Combi 2636 Combi 2
Product Code779658677965877796588
Natural gas or LPGYesYesYes
Inlet supply pressure (natural gas) (mbar (nominal))202020
Maximum Gas Rate (G20) Omax (m³ / hr)2.613.263.9
kW (max) Gross (OnHs)20.625.725.7
kW (min) Gross (OnHs)4.967.2
kW (Max) (Pn)202525
kW (Min) (Pn)4.85.87.2
kW (Max) (Pnc)21.827.127.1
kW (Min) (Pnc)5.26.37.6
Heat Input domestic hot water (DHW) (kW max gross (OnwHs))27.430.936.9
Heat Output domestic hot water (DHW) (kW max)243036
Water heating efficiency classAAA
Permanent live requiredYesYesYes
External fuse rating (on connection board) (Amps)F0.5A L250VPF0.5A L250VPF0.5A L250VP
Pump overrunYesYesYes
Integral ‘boiler only’ frost thermostatYesYesYes
Maximum DHW flow rate (Delta T @35’C rise) (l/min)10.212.215
Minimum DHW flow rate required (l/min)222
Minimum operating DHW pressure required (bar)0.50.50.5
Integral expansion vessel – Size (litres)777
Maximum capacity of the CH system (litres)100100100
Integral automatic bypassYesYesYes
Installer Lift Weight (kg)282930

Baxi range information

Discuss this range →
Assure 500 Combi 2 boiler

Combi

Baxi Assure 500 Combi 2

First, we check how this range would suit your Baxi boiler installation. A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.

Maximum DHW flow rate (Delta T @ 35’C rise)Vmin · 10.2 · 12.2 · 15
Water heating efficiency classA · A · A
Compare model specifications
Product ModelBaxi Assure 524 Combi 2Baxi Assure 530 Combi 2Baxi Assure 536 Combi 2
Product code781430978143107814311
Natural Gas or LPGYesYesYes
Inlet supply pressure (NG)202020
Maximum gas rate (G20)2.613.263.9
Heat Input CHkW (min) gross (QnHs)20.625.725.7
Heat Input CHkW (min) gross (QnHs)4.967.2
Heat output CH (non-condensing)kW (max) (pn)202525
Heat output CH (condensing)kW (max) (pn)4.85.87.2
Heat input domestic hot waterkW (max)gross27.430.936.9
Heat input domestic hot waterkW (max)243036
Water heating efficiency classAAA
Permanent live requiredYesYesYes
Pumps overrunYesYesYes
Maximum DHW flow rate (Delta T @ 35’C rise)Vmin10.212.215
Minimum DHW flow rate requiredVmin222
Minimum operating DHW pressure requiredbar0.50.50.5
Integral expansion vesselSize (litres)777
Maximum capacity of the CH systemLitres100100100
Integral automatic bypassYesYesYes

Baxi range information

Discuss this range →
Baxi MainEco Compact Combi boiler

Combi

Baxi MainEco Compact Combi

Also, we compare space and hot-water requirements for your Baxi boiler installation. A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.

Heat output domestic hot waterkW Max (Pn) · 25.00 · 30.93
Space heating efficiency classA · A
Compare model specifications
Main Eco Compact CombiUnitsMain Eco CompactCombi 25kWMain Eco CompactCombi 30kW
Sales code (boiler only)77145197714161
Reset buttonYesYes
User adjustable DHW temperatureYesYes
User adjustable CH temperatureYesYes
LED temp/status/fault diagnosis displayYesYes
Natural gasYesYes
Nominal inlet supply pressurembar2020
Maximum gas ratem3/h2.713.26
Propane LPGNoNo
Heat input central heating (CH)kW Max Gross(QnHs)22.8622.86
kW Min Gross(QnHs)6.876.87
Heat output CH non-condensingkW Max (Pn)20.0020.00
kW min (Pn)6.206.20
Heat output CH condensingkW max (Pnc)21.1621.20
kW min (Pnc)6.706.70
Heat input domestic hot waterkW Max Gross (QnwHs)25.7730.00
Heat output domestic hot waterkW Max (Pn)25.0030.93
NOxclass66
Space heating efficiency classAA
Water heating declared load profileXLXL
Water heating efficiency classAA
Seasonal space heating energy efficiency%9393
Electrical supplyVolts/Hz230/50230/50
Permanent live requiredYesYes
Fitted electrical cableNoNo
Power consumptionWatts6868
External fuse ratingAmps33
Internal fuse ratingAmpsF2AH250VF2AH250V
Ingress protection ratingIPX5DIPX5D
Integral ‘boiler only’ frost thermostatYesYes
Multifit Pre-Plumb jig (7682545)YesYes
Isolating valvesYesYes
Gas supply connectionmm2222
Central heating connectionsmm2222
Domestic hot water connectionsmm1515
Condensate drain connectionmm21.5021.50
Safety discharge connectionmm1515
Safety discharge pressurebar33
Temporary rigid filling loop includedYesYes
Domestic hot water output (raised 35°C) (max)l/min10.212.2
Domestic hot water operating flow rate (min)l/min2*2*
Domestic hot water operating pressure (min)bar0.50.5
Domestic hot water system pressure (max)bar88
CH safety discharge pressurebar33
Integral automatic bypassYesYes
Integral expansion vessel capacitylitres77
Max capacity of central heating systemlitres100100
Compartment ventilation requirementNoNo
CH system inhibitor requiredYesYes
24 hour pump exerciseYesYes
Pump overrunYesYes
Concentric flue diametersmm60/100
Standard horizontal flue kit length (60/100mm)mm685685
Max equiv length horizontal/vertical (60/100mm)m1010
Equivalent length per 135º bendm0.500.50
Equivalent length per 93º bendm1.001.00
Max installation lift weightkg2929
Gross packaged boiler weightkg3232

Baxi range information

Discuss this range →
Baxi Duo-tec Compact Combi boiler

Combi

Baxi Duo-tec Compact Combi boilers

Before your Baxi boiler installation, we assess the existing system and recommend a suitable model. A compact cupboard-fit combi option with compatibility for Baxi uSense 2 controls. We explain the controls, water supply and installation layout during your survey.

FormatCombi
Model comparisonOpen the specifications below
Compare model specifications
Case dimensionsPublished value
Width (mm)395
Height (mm)700
Depth (mm)285

Baxi range information

Discuss this range →
Platinum Compact Combi boiler

Combi

Baxi Platinum Compact Combi

First, we check how this range would suit your Baxi boiler installation. A compact cupboard-fit combi option with compatibility for Baxi uSense 2 controls. We explain the controls, water supply and installation layout during your survey.

FormatCombi
Model comparisonOpen the specifications below
Compare model specifications
Case dimensionsPublished value
Width (mm)395
Height (mm)700
Depth (mm)285

Baxi range information

Discuss this range →

Gas regular boilers

400 Heat boiler

Regular

Baxi 400 Heat

Also, we compare space and hot-water requirements for your Baxi boiler installation. A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.

SAP 2009 Annual Efficiency (PCDB/SEDBUK) %89.2 · 89.2 · 89.1 · 89.1
Compare model specifications
Product Model15kW18kW24kW30kW
Product Code7668933766893476689357668936
Operating mode selector switch with reset (Yes/No)YesYesYesYes
User adjustable CH temperature -Range – e.g. 30ºC to 80ºC (+/- 5ºC)YesYesYesYes
LED status/fault diagnosis display (Yes/nNo)YesYesYesYes
SAP 2009 Annual Efficiency (PCDB/SEDBUK) %89.289.289.189.1
NOx class (1-5)5556
NOx (mg/kWh)20212321
Sound Power Level, Indoors (LWA dB)33343549
Space Heating Efficiency ClassAAAA
Heat Input CH -kW max gross (QnHs)18.3221.7528.6234.35
Heat Input CH – kW min gross (QnHs)8.598.598.598.59
Heat Output CH (non condensing) – kW max (Pn)16192530
Heat Output CH (non condensing) – kW min (Pn)7.57.57.510.1
Gas supply pipe size (mm)22222222
Inlet supply pressure (natural gas) – mbar20202020
Maximum gas rate (m3/hr)1.752.072.733.27
Compartment ventilation requiredNoNoNoNo
Flow / return pipe size (mm)22222222
Condensate discharge pipe (mm)21.521.521.521.5
Electrical supply – Volts/Hz230V/50Hz230V/50Hz230V/ 50Hz230V/ 50Hz
Permanent live required (Yes/No)NoNoNoNo
Switched live (Yes/No)YesYesYesYes
Electrical power cable fitted as standard (1m of 3 core)YesYesYesYes
Power consumption (Watts)20233344
External fuse rating (Amps)3333
Internal fuse rating1.6T1.6T1.6T1.6T
Boiler IP rating (electrical protection) -Approval categoryIPX4DIPX4DIPX4DIPX4D
Pump overrun (Yes/No)NoNoNoNo
Standard telescopic concentric flue (Length in mm)315-500315-500315-500315-500
Standard in-case rear telescopic concentric flue (Length in mm)220-345220-345220-345220-345
Horizontal concentric (60/100mm) – Max equivalent length (m)6666
Horizontal concentric (60/100mm) – Reduction per 135º bend (m)0.50.50.50.5
Horizontal concentric (60/100mm) – Reduction per 93º bend (m)1111
Installer lift weight -Max (kg)17.417.417.419.5
Gross packaged boiler weight (kg)21.521.521.521.5

Baxi range information

Discuss this range →
Baxi 800 Heat boiler

Regular

Baxi 800 Heat boilers

Before your Baxi boiler installation, we assess the existing system and recommend a suitable model. A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.

SAP 2009 annual efficiency (PCDB/SEDBUK) %89.2 · 89.2 · 89.1 · 89.1
Compare model specifications
Product Model16192530
Product Code7749866789883277498687749869
Operating mode selector switch with reset (Yes/No)YesYesYesYes
User adjustable CH temperature (Range – e.g. 45° to 82°)YesYesYesYes
LED temp/status/fault diagnosis display (Yes/No)YesYesYesYes
Baxi twin channel wired programmer -7212443OptionalOptionalOptionalOptional
Baxi room thermostat -720971601OptionalOptionalOptionalOptional
Boiler Plus ErP (%)939393
SAP 2009 annual efficiency (PCDB/SEDBUK) %89.289.289.189.1
NOx class6666
NOx (mg/kWh)20252424
Sound Power Level, Indoors (LWA dB)39414549
Space Heating Efficiency ClassAAAA
Heat Input CH – kW max gross (QnHs)18.3221.7528.6234.35
Heat Input CH – kW min gross (QnHs)8.598.598.598.59
Heat Output CH (non condensing) kW (Pn)16192530
Heat Output CH (non condensing) kW (Pn)7.56.47.57.5
Gas supply connection (mm)22222222
Inlet supply pressure (natural gas) mbar20202020
Maximum gas rate (m3/hr)1.752.072.733.27
Compartment ventilation required (Yes/No)NoNoNoNo
Flow / return pipe size (mm)22222222
Condensate discharge pipe size (mm)21.521.521.521.5
Electrical supply (Volts/Hz)230V/50Hz230V/ 50Hz230V/50Hz230V/50Hz
Permanent live required (Yes/No)NoNoNoNo
Switched live (Yes/No)YesYesYesYes
Electrical power cable fitted as standard (1m of 3 core)YesYesYesYes
Power consumption (Watts)20233344
External fuse rating (Amps)3333
Internal fuse rating1.6T1.6T1.6T1.6T
Boiler IP rating (electrical protection) -Approval categoryIPX4DIPX4DIPX4DIPX4D
Pump overrun (Yes/No)NoNoNoNo
Standard telescopic concentric flue (Length in mm)315-500315-500315-500315-500
Horizontal and Vertical concentric (60/100 mm) – Max equivalent length (m)6666
Horizontal and Vertical concentric (60/100 mm) – Reduction per 135° bend (m)0.50.50.50.5
Horizontal and Vertical concentric (60/100 mm) – Reduction per 93° bend (m)1111
Installer lift weight (boiler) Max (kg)17.417.417.419.5
Gross packaged boiler weight (kg)21.319.421.321.3

Baxi range information

Discuss this range →
600 Heat boiler

Regular

Baxi 600 Heat

First, we check how this range would suit your Baxi boiler installation. A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.

SAP 2009 annual efficiency (PCDB/SEDBUK) %89.2 · 89.2 · 89.1
Compare model specifications
Product Model16 Heat19 Heat25 Heat
Product Code771199977120207712022
Operating mode selector switch with reset (Yes/No)YesYesYes
User adjustable CH temperature (Range – e.g. 45° to 82°)YesYesYes
LED temp/status/fault diagnosis display (Yes/No)YesYesYes
Baxi twin channel wired programmer – 7212443OptionalOptionalOptional
Baxi room thermostat – 720971601OptionalOptionalOptional
Boiler Plus ErP (%)939393
SAP 2009 annual efficiency (PCDB/SEDBUK) %89.289.289.1
NOx class666
NOx (mg/kWh)202124
Sound Power Level, Indoors (LWA dB)394145
Space Heating Efficiency ClassAAA
Heat Input CH – kW max gross (QnHs)18.3221.7528.62
Heat Input CH – kW min gross (QnHs)8.598.598.59
Heat Output CH (non condensing) – kW (Pn)161925
Heat Output CH (non condensing) – kW (Pn)7.57.57.5
Gas supply connection (mm)222222
Inlet supply pressure (natural gas) – mbar202020
Maximum gas rate (m3/hr)1.752.072.73
Compartment ventilation required (Yes/No)NoNoNo
Flow / return pipe size (mm)222222
Condensate discharge pipe size (mm)21.521.521.5
Electrical supply – Volts/Hz230V/50Hz230V/50Hz230V/50Hz
Permanent live required (Yes/No)NoNoNo
Switched live (Yes/No)YesYesYes
Electrical power cable fitted as standard (1m of 3 core)YesYesYes
Power consumption (Watts)202333
External fuse rating (Amps)333
Internal fuse rating1.6T1.6T1.6T
Boiler IP rating (electrical protection) – Approval categoryIPX4DIPX4DIPX4D
Pump overrun (Yes/No)NoNoNo
Standard telescopic concentric flue (Length in mm)315-500315-500315-500
Horizontal and Vertical concentric (60/100 mm) – Max equivalent length (m)666
Horizontal and Vertical concentric (60/100 mm) – Reduction per 135° bend (m)0.50.50.5
Horizontal and Vertical concentric (60/100 mm) – Reduction per 93° bend (m)111
Installer lift weight (boiler) – Max (kg)17.417.417.4
Gross packaged boiler weight (kg)19.519.519.5

Baxi range information

Discuss this range →
Baxi Assure Heat boiler

Regular

Baxi Assure Heat

Also, we compare space and hot-water requirements for your Baxi boiler installation. A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.

FormatRegular
Model comparisonOpen the specifications below
Compare model specifications
Product ModelBaxi Assure 16 HeatBaxi Assure 19 HeatBaxi Assure 25 Heat
Product code774944777494487749449
Natural GasYesYesYes
Propane LPGN/AN/AN/A
Inlet supply pressure202020
Maximum gas rate (G20)1.752.072.73
Heat Input CHkW (min) gross (QnHs)18.3221.7528.62
Heat Input CHkW (min) gross (QnHs)8.598.598.59
Heat output CH (non-condensing)kW (max) (pn)161925
Heat output CH (non-condensing)kW (max) (pn)7.57.57.5
Permanent live requiredNoNoNo
External fuse rating333
Pumps overrunNoNoNo

Baxi range information

Discuss this range →
MainEco Compact Heat boiler

Regular

Baxi MainEco Compact Heat boilers

Before your Baxi boiler installation, we assess the existing system and recommend a suitable model. A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.

Space heating efficiency classA · A · A · A
Compare model specifications
Main Eco Compact HeatUnitsMain Eco CompactHeat 15kWMain Eco CompactHeat 18kWMain Eco CompactHeat 24kWMain Eco CompactHeat 30kW
Sales code (boiler only)Controls and accessories7712025771202677120287712029
Operating mode selector switch with resetYesYesYesYes
User adjustable CH temperatureRange 30°C to 80°CYesYesYesYes
LED temp/status/ fault diagnosis displayYesYesYesYes
NOx class6666
NOxmg/kWh20212424
Sound power level, indoorsLWA dB33343737
Space heating efficiency classAAAA
Heat input central heating (CH)kW max gross (QnHs) – kW min gross (QnHs)18.32 – 8.5921.75 – 8.5928.62 – 8.5934.35 – 8.59
Heat output CH (non-condensing)kW max (Pn) – kW min (Pn)16 – 7.519 – 7.525 – 7.530 – 7.5
Gas supply pipe sizemm22222222
Inlet supply pressure (natural gas)mbar20202020
Maximum gas ratem3/hr1.752.072.733.27
Compartment ventilation requiredNoNoNoNo
Flow/return pipemm22222222
Condensate discharge pipe connectionmm21.521.521.521.5
Electrical supplyVolts / Hz230V / 50Hz230V / 50Hz230V / 50Hz230V / 50Hz
Permanent live requiredNoNoNoNo
Power consumptionWatts20233344
External fuse ratingAmps3333
Internal fuse rating1.6T1.6T1.6T1.6T
Boiler IP rating (electrical protection)Approval CategoryIPX4DIPX4DIPX4DIPX4D
Pump overrunNoNoNoNo
Standard telescopic concentric fluemm315-500315-500315-500315-500
Max equivalent length (m)6666
Reduction Per 135º bend (m)0.50.50.50.5
Reduction Per 93º bend (m)1111
Gross packaged boiler weight(Max)kg19.519.519.521.5
Maximum installation lift weightkg17.417.417.419.5

Baxi range information

Discuss this range →
Potterton Titanium Heat boiler

Regular

Potterton Titanium Heat

First, we check how this range would suit your Baxi boiler installation. A Baxi-group heat-only option for cylinder-based heating. We inspect the pump, valves and existing arrangement before specifying the replacement.

FormatRegular
Model comparisonOpen the specifications below
Compare model specifications
Case dimensionsPublished value
Width (mm)370
Height (mm)625
Depth (mm)270

Baxi range information

Discuss this range →

Gas system boilers

800 System 2 boiler

System

Baxi 800 System 2

Also, we compare space and hot-water requirements for your Baxi boiler installation. A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.

Maximum DHW flow rate (Delta T @ 35c rise) (I/min)n/a · n/a · n/a
Water heating efficiency classA · A · A
Compare model specifications
Product model18 System24 System30 System
Product code781431378143147814315
Natural Gas or LPGYesYesYes
Inlet supply pressure (natural gas) mbar(nominal)202020
Maximum gas rate (G20) Qmax (m3/hr)1.972.613.26
Heat input CHkW (max) gross (QnHs)18.624.730.9
Heat input CHkW (min) gross (QnHs)4.94.96
Heat output CH (non-condensing) – kW (max) (Pn)182430
Heat output CH (non-condensing) – kW (min) (Pn)4.84.85.8
Heat output CH (condensing) – kW (max) (Pnc)19.926.332.4
Heat output CH (condensing) – kW (min) (Pnc)5.25.26.4
Heat input domestic hot water (DHW) – kW (max) gross (QnwHs)n/an/an/a
Heat input domestic hot water (DHW) – kW (max)n/an/an/a
Water heating efficiency classAAA
Permanent live requiredYesYesYes
Pump overrunYesYesYes
Integral ‘boiler only’ frost thermostatYesYesYes
Maximum DHW flow rate (Delta T @ 35c rise) (I/min)n/an/an/a
Minimum DHW flow rate required (I/min)222
Minimum operating DHW pressure required (bar)0.50.50.5
Integral expansion vessel (litres)777
Maximum capacity of CH system (litres)100100100
Installer lift weight (boiler) (kg)293030

Baxi range information

Discuss this range →
Baxi 600 System 2 boiler

System

Baxi 600 System 2 boilers

Before your Baxi boiler installation, we assess the existing system and recommend a suitable model. A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.

Maximum DHW flow rate (Delta T @ 35c rise) (I/min)n/a · n/a · n/a
Water heating efficiency classA · A · A
Compare model specifications
Product model15 System18 System24 System
Product code779868778020207802241
Natural Gas or LPGYesYesYes
Inlet supply pressure (natural gas) mbar(nominal)202020
Maximum gas rate (G20) Qmax (m3/hr)1.641.972.61
Heat input CHkW (max) gross (QnHs)15.518.624.7
Heat input CHkW (min) gross (QnHs)4.94.94.9
Heat output CH (non-condensing) – kW (max) (Pn)151824
Heat output CH (non-condensing) – kW (min) (Pn)4.84.84.8
Heat output CH (condensing) – kW (max) (Pnc)16.319.926.3
Heat output CH (condensing) – kW (min) (Pnc)5.25.25.2
Heat input domestic hot water (DHW) – kW (max) gross (QnwHs)n/an/an/a
Heat input domestic hot water (DHW) – kW (max)n/an/an/a
Water heating efficiency classAAA
Permanent live requiredYesYesYes
Pump overrunYesYesYes
Integral ‘boiler only’ frost thermostatYesYesYes
Maximum DHW flow rate (Delta T @ 35c rise) (I/min)n/an/an/a
Minimum DHW flow rate required (I/min)222
Minimum operating DHW pressure required (bar)0.50.50.5
Integral expansion vessel (litres)777
Maximum capacity of CH system (litres)100100100
Installer lift weight (boiler) (kg)282930

Baxi range information

Discuss this range →
Baxi MainEco Compact System boiler

System

Baxi MainEco Compact System

First, we check how this range would suit your Baxi boiler installation. A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.

Seasonal space heating energy efficiency% · 93 · 93
Compare model specifications
Main Eco Compact SystemUnitsMain Eco Compact System 15kWMain Eco Compact System 18kW
Sales code (boiler only)77146057714606
Reset switchYesYes
User adjustable CH temperatureYesYes
LED operating status displayYesYes
Natural GasYesYes
Nominal inlet supply pressurembar2020
Maximum gas ratem3/hr1.641.96
Heat input central heating (CH)kW max gross (QnHs)17.1620.60
kW min gross (QnHs)5.155.15
Heat output CH non-condensingkW max (Pn)15.0018.00
kW min (Pn)4.504.50
Heat output CH condensingkW max (Pnc)16.219.4
kW min (Pnc)4.94.9
NOxclass66
Sound power level, indoorsLWA dB4951
Seasonal space heating energy efficiency%9393
Electrical supplyVolts/Hz230/50230/50
Permanent live requiredYesYes
Switched liveYesYes
Power consumptionWatts4656
External fuse ratingAmps33
Internal fuse ratingF2HA250VF2HA250V
Boiler IP rating (electrical protection)Approval categoryIPX5DIPX5D
Integral ‘boiler only’ frost thermostatYesYes
Pump overrunYesYes
Multifit Pre-Plumb jig (7682545)YesYes
Isolating valvesYesYes
Gas supply connectionmm2222
Central heating connectionsmm2222
Condensate drain connectionmm21.521.5
Safety discharge connectionmm1515
Safety discharge pressurebar33
Integral automatic bypassYesYes
Integral expansion vessellitres77
Maximum capacity of CH systemlitres100100
24hr pump exerciseYesYes
Pump overrunYesYes
Concentric flue diametermm60/10060/100
Standard horizontal flue kit length (ø 60/100)mm685685
Maximum equivalent vertical length (ø 60/100)m1010
Equivalent length per 135° bendm0.500.50
Equivalent length per 93° bendm11
Gross packaged boiler weightkg31.231.2
Maximum installation lift weightkg28.0628.06

Baxi range information

Discuss this range →
Assure 500 System 2 boiler

System

Baxi Assure 500 System 2

Also, we compare space and hot-water requirements for your Baxi boiler installation. A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.

Maximum DHW flow rate (Delta T @ 35’C rise)Vmin · N/A · N/A · N/A
Water heating efficiency classA · A · A
Compare model specifications
Product ModelBaxi Assure 515 System 2Baxi Assure 518 System 2Baxi Assure 524 System 2
Product code781431878143197814320
Natural Gas or LPGYesYesYes
Inlet supply pressure (NG)202020
Maximum gas rate (G20)1.641.972.61
Heat Input CHkW (max) gross (QnHs)15.518.624.7
Heat Input CHkW (min) gross (QnHs)4.94.94.9
Heat output CH (non-condensing)kW (max) (pn)151824
Heat output CH (non-condensing)kW (min) (pn)4.84.84.8
Heat output CH (condensing)16.319.926.3
Heat output CH (condensing)5.25.25.2
Heat input domestic hot waterN/AN/AN/A
Heat input domestic hot waterN/AN/AN/A
Water heating efficiency classAAA
Permanent live requiredYesYesYes
Pumps overrunYesYesYes
Integral ‘boiler only’ frost thermostatYesYesYes
Maximum DHW flow rate (Delta T @ 35’C rise)VminN/AN/AN/A
Minimum DHW flow rate requiredVmin222
Minimum operating DHW pressure requiredbar0.50.50.5
Integral expansion vesselSize (litres)777
Maximum capacity of the CH systemLitres100100100
Integral automatic bypassYesYesYes

Baxi range information

Discuss this range →
Baxi Megaflo Compact System boiler

System

Baxi Megaflo Compact System boilers

Before your Baxi boiler installation, we assess the existing system and recommend a suitable model. A compact system-boiler option for a home with a separate hot-water cylinder. We assess the cylinder, heating load and controls together.

FormatSystem
Model comparisonOpen the specifications below
Compare model specifications
Case dimensionsPublished value
Width (mm)395
Height (mm)700
Depth (mm)285

Baxi range information

Discuss this range →

Compare figures carefully, because manufacturers publish different units and test conditions. For example, hot-water flow at a 35°C temperature rise differs from a figure measured at 40°C. In addition, ErP efficiency and seasonal efficiency to DIN use different test methods. Therefore, we explain the relevant figures before matching the exact model to your quotation.

What matters when choosing Baxi boilers?

First, we calculate your home’s heating requirement, because radiator numbers alone cannot tell us the right boiler output. In addition, we compare the boiler’s minimum output so it can respond to smaller heating demands.

Next, we assess hot water, because the available water supply and temperature rise affect a combi’s flow at your taps. By contrast, a cylinder-based system needs the right storage capacity and recovery. Therefore, we discuss your showers, baths and daily routine together.

Also, we check the installation space, service access, flue route and controls. Although case dimensions are useful, the installation needs working room around the appliance too. As a result, your quotation covers a complete, practical boiler replacement.

Baxi boiler installation planned around the home

Choose the right Baxi boiler type

Baxi combi boiler installation options

Combi boilers

A combi supplies central heating and heats tap water on demand. Therefore, we check the mains-water flow and how you use your showers before choosing the output.

Discuss your boiler type →
Baxi system boiler installation options

System boilers

A system boiler works with a separate hot-water cylinder. As a result, we size the boiler and stored hot water together, including the cylinder controls and recovery needs.

Discuss your boiler type →
Baxi regular boiler installation options

Regular boilers

A regular or heat-only boiler works with a separate cylinder and external system components. First, we check the pump, valves and any tanks, then explain the replacement work.

Discuss your boiler type →

Natural gas and LPG boiler installations

For natural gas, we check the existing supply, boiler position and heating system. In addition, Baxi offers LPG options within the appropriate ranges. We specify the correct model and fuel setup for your off-mains home.

For example, an LPG version or conversion applies to particular models rather than every boiler in a family. Therefore, our survey confirms the exact appliance and configuration before we quote. Our Gas Safe registered team completes the installation and commissioning.

Your Baxi boiler installation, step by step

01

Survey your home

First, we discuss your rooms, heating and hot-water use. Also, we inspect the boiler, supply, radiators and controls, so your Baxi boiler installation has a clear starting point.

02

Compare the options

Next, we explain suitable ranges, outputs and controls. Therefore, your quotation sets out the chosen boiler, fitting work and any system changes. You can then decide with a clear picture of the work.

03

Prepare and fit carefully

Then, we prepare the heating system and address cleaning and filtration. In addition, we fit the boiler, flue, pipework and controls with attention to service access and the finished appearance.

04

Commission and hand over

Finally, we test and commission the appliance, complete the records and explain the settings. Also, we show you the heating schedule and everyday controls, then help you arrange ongoing servicing.

INDEPENDENTLY REVIEWED

Heating work backed by hundreds of five-star reviews

For example, customers repeatedly mention punctual engineers, tidy workmanship and clear advice before, during and after their heating project.

★★★★★
The gas-boiler service was completed efficiently and the certificate arrived by email almost immediately.
F. Gillespie-WalkerGoogle Reviews — Google customer review
★★★★★
An older-property boiler upgrade finished on time, with tidy workmanship, punctual attendance and a flexible approach.
Which? Trusted TradersVerified heating customer, Oxfordshire
★★★★★
A last-minute boiler service was arranged quickly and completed efficiently by a team the customer readily recommends.
K. BrayWhich? Trusted Traders — Verified boiler-service customer

Review totals checked September 2026. Read the complete independent feedback on Google and Which? Trusted Traders.

Baxi boiler questions

Can Oxyplumb install a Baxi boiler?

We install Baxi boilers across Oxfordshire, including straightforward replacements and wider heating upgrades. First, tell us about your current appliance so we can understand what you want to improve.

Which boiler output should I choose?

First, consider your home’s heating demand and hot-water use. Therefore, we assess the property, water supply and existing system before recommending an output. After all, the largest model is not automatically the right choice.

Can you replace a boiler from another brand?

Your existing boiler can be from another brand, because we plan the replacement around your heating system. First, we inspect the system, explain the options and quote for the work needed to fit your chosen Baxi replacement.

Do you service and repair other boiler makes?

Our maintenance work also covers a broad range of boiler manufacturers, including older and less familiar makes. First, tell us your boiler’s make, model and fuel, so we can arrange the right engineer.

Local Baxi boiler installation and ongoing care

For example, our team covers Faringdon, Wantage, Abingdon, Stanford in the Vale, Oxford, Bampton, Clanfield, Witney, Cumnor, Carterton, Uffington and Kingston Bagpuize. Choose your area to find its dedicated installation, servicing and repair pages.

Also, we maintain and repair boilers from a broad range of manufacturers. Explore our boiler servicing and boiler repair services, or compare our other manufacturer guides below.

Ready to choose your new Baxi boiler?

First, tell Oxyplumb about your home and the work you have in mind. Then, we will help you choose the right boiler and provide a clear installation quotation.